Leave Your Message

Iziteshi Ezincane Ezingakhula Zokusetshenziswa Ezimbonini

Izixazululo Zokusabalalisa Amandla Ezingakhula, Ezisebenzayo​

Isiteshi esincane siyisisombululo esisha, esonga isikhala esenzelwe ukuthuthukisa ukusatshalaliswa kwamandla ezindaweni zasemadolobheni, zezimboni, kanye nezikude. Njengoba zihlanganisa izingxenye ezibalulekile njenge-transformers, i-switchgear, kanye nezinhlelo zokuvikela esakhiweni esisodwa, esinomodular, lezi ziteshi ezincane zinikeza ukudluliselwa kwamandla okuthembekile, okusebenza kahle kakhulu okunezinyathelo ezincane. Zakhiwe ukuze zihlangabezane namazinga omhlaba wonke (i-IEC, i-IEEE), iziteshi zethu ezincane zihlanganisa ukuphepha, ukusebenza kahle, kanye nokuzivumelanisa nezimo kwezinhlelo zokusebenza ezahlukahlukene.

    Izici Eziyinhloko Nezinzuzo

    Umklamo Osebenzisa Isikhala
    Ukwakhiwa kwe-modular kunciphisa usayizi obonakalayo ngamaphesenti afinyelela kwangu-60 uma kuqhathaniswa neziteshi ezincane zendabuko, okwenza ukufakwa kube nokwenzeka ezindaweni ezilinganiselwe njengemigwaqo yasemadolobheni, izitshalo zezimboni, noma imiphakathi ekude. Amayunithi ahlanganiswe ngaphambilini anciphisa isikhathi sokwakha endaweni.
    .Ukusebenza Okuphezulu Nokuthembeka​​
    Zihlonyiswe ngama-transformer acwiliswe ngowoyela noma ohlobo olomile, ama-vacuum circuit breaker, kanye ne-SF6 gas-insulated switchgear (GIS), lezi ziteshi ezincane ziqinisekisa ukulawulwa kwamandla okusebenzayo (11kV kuya ku-33kV) kanye nokuvikelwa emaphutheni. Izinhlelo zokuvikela eziqinile kanye nokupholisa zithuthukisa ukuqina ezindaweni ezishisayo.
    .Ukuzenzakalela Okuhlakaniphile Nokuqapha​​
    Izinhlelo ezingasetshenziswa yi-IoT zinikeza idatha yesikhathi sangempela mayelana nogesi, ugesi wamanje, izinga lokushisa, kanye nokutholwa kwamaphutha. Amandla okulawula kude nge-SCADA ahlangana namanethiwekhi e-smart grid, okuvumela ukulungiswa kokubikezela kanye nokunciphisa isikhathi sokungasebenzi.
    .Ukuthunyelwa Okusheshayo Nokukhuliswa
    Amayunithi ahlanganiswe efektri futhi ahlolwe angafakwa ngezinsuku ezimbalwa, okusheshisa isikhathi sephrojekthi. Imiklamo ekwazi ukwandiswa ivumela ukuthuthukiswa kwamandla (kufika ku-50 MVA) ngaphandle kokushintsha lonke uhlelo, okusekela ukukhula kwamandla kwesikhathi eside.
    .Kunobungani Nemvelo Futhi Kubiza Kahle​
    Ukusebenza komsindo ophansi (
    I-Transformer Ecwiliswe Kuwoyela we-Cooper Imvamisa Ephakeme 10001I-Transformer Ecwiliswe Kuwoyela we-Cooper Imvamisa Ephakeme 10002I-Transformer Ecwiliswe Kuwoyela we-Cooper Imvamisa Ephakeme 10003
    Iziteshi Ezincane Ezingakhula Zokusetshenziswa Ezimbonini
    • Iziteshi Ezincane Ezingakhula Zokusetshenziswa Ezimbonini
    • Iziteshi Ezincane Ezingakhula Zokusetshenziswa Ezimbonini01
    • Iziteshi Ezincane Ezingakhula Zokusetshenziswa Ezimbonini02
    • Iziteshi Ezincane Ezingakhula Zokusetshenziswa Ezimbonini03
    • Iziteshi Ezincane Ezingakhula Zokusetshenziswa Ezimbonini04
    • Iziteshi Ezincane Ezingakhula Zokusetshenziswa Ezimbonini05
    I-Transformer Ecwiliswe Kuwoyela we-Cooper01

    Izicelo

    Ingqalasizinda Yasemadolobheni: Iziteshi ezincane zezindawo zasemadolobheni, izindawo zokuhweba, kanye namadolobha ahlakaniphile.
    Izindawo Zezimboni: Ukunikezwa kwamandla okuzinzile kwezitshalo zokukhiqiza, izimayini, kanye nezikhungo zedatha.
    .Izindawo Ezikude: Ukuthunyelwa okusheshayo ezindaweni ezingaphandle kwegridi noma ezisengozini yenhlekelele.
    Amandla Avuselelekayo: Ukuhlanganiswa namapulazi elanga/omoya ukuze kuxhunywe kahle igridi.

    Imininingwane Yobuchwepheshe

    Ibanga Le-Voltage: 11kV kuya ku-33kV (i-voltage ephakathi nendawo).
    .Umthamo: I-VAT engu-5 kuya ku-50 i-VAT.
    .Imvamisa: 50Hz/60Hz.
    .Ukupholisa: Ukupholisa komoya wemvelo (AN) noma okuphoqelelwe (AF).
    .Ukuthobela imithetho: Isitifiketi se-IEC 62271, i-IEEE 1526, kanye ne-ISO 9001/14001.

    Ukuqinisekisa ikhwalithi

    Ukuhlolwa okuqinile kufaka phakathi amandla e-dielectric, ukumelana ne-short-circuit, kanye nokulingisa ukuphakama kwezinga lokushisa.
    Iqinisekiswe yi-KEMA, DEKRA, kanye ne-TÜV ngokuphepha nokuthembeka.

    Kungani Kufanele Ukhethe Thina?

    Iminyaka engu-25+ yobuchwepheshe: Imiklamo eqinisekisiwe yokushisa okukhulu, umswakama, kanye nezindawo zokuzamazama komhlaba.
    .Izinsizakalo Zokugcina: Ukusekelwa kokuklama, ukufaka, kanye nokugcinwa komjikelezo wokuphila.
    .Izimali Eziguquguqukayo: Izinketho zokuqasha kanye nokukhokha njengoba uqhubeka ukuze kube nokuguquguquka kwesabelomali.

    Izixazululo Zenziwe Ngokwezifiso

    Ukuzivumelanisa Nemvelo: Izindawo zokuvala ezingamelani nokugqwala zezindawo ezisogwini noma imiklamo engaqhumi yezindawo zikawoyela/igesi.
    .Izinhlelo Ezihlanganisiwe: Ukuhlanganiswa kwesitoreji samandla avuselelekayo (isb., amabhange ebhethri) kumagridi e-hybrid.
    I-Transformer Ecwiliswe Kuwoyela we-Cooper02I-Transformer Ecwiliswe Kuwoyela we-Cooper03I-Transformer Ecwiliswe Kuwoyela we-Cooper04I-Transformer Ecwiliswe Kuwoyela we-Cooper05

    Izinzuzo zomkhiqizo

    1. Izinto Eziyinhloko kanye Nomklamo Wokugoba​
    Izinto Eziyinhloko​
    Ama-Cores e-Amorphous Alloy:
    Ukulahleka kwensimbi okuphansi kakhulu (okungaphansi kuka-70–80% kunensimbi ye-silicon) kunciphisa ukuchithwa kwamandla, okubalulekile ekwakhiweni okuhlangene nokusebenza kahle kakhulu.
    Ukungena okuphezulu kanye nokunciphisa amandla kagesi cishe ku-zero kunciphisa umsindo, okulungele izindawo zasemadolobheni noma zokuhlala.
    Insimbi Ye-Silicon Eqondiswe Kuma-Grain (CRGO) Ebandayo:
    Ama-lamination asikwe nge-laser anciphisa ukulahlekelwa kwamanje kwe-eddy, afinyelela amazinga okusebenza kahle afinyelela ku-98.5% ezindaweni ezilinganiselwe.
    Ubuningi be-magnetic flux obuphezulu busekela izinhlelo zokusebenza ezincane ze-high-voltage (11kV–33kV).
    Umklamo Wokugoba
    Amawindi e-Foil anokupholisa okugeleza kwamafutha:
    Ama-winding e-copper/aluminium foil anciphisa ukuvuza kwamandla kanye namandla okujikeleza okufushane. Iziteshi zikawoyela ezihlanganisiwe zithuthukisa ukushabalaliswa kokushisa ezindaweni ezivalekile.
    Izendlalelo ezihlanganisiwe zinciphisa ukucindezeleka kwamandla kagesi aphakathi kwamajika, zithuthukisa ukuqina kwe-short-circuit (kufika kumaphutha angalingani angama-50 kA).
    Amawindingi e-Litz Wire anezingqimba:
    Intambo ye-Litz enezintambo eziningi inciphisa imiphumela yesikhumba kanye nokusondela, inciphisa ukumelana kwe-AC ekusebenzeni kwemvamisa ephezulu (isb., izixhumanisi ze-HVDC).
    Amalungiselelo e-Compact Disc/Winding:
    Ama-helical noma ama-disc windings enza ngcono ukusetshenziswa kwesikhala, ahlanganiswe ne-graded insulation ukuze amelane nokushukuma kombani (≥1.2/50 μs).
    2. Izinhlelo Zokuvikela​
    Ukufakwa Kokumbozwa Kwephepha Elihlanganisiwe Lamafutha:
    Iphepha le-cellulose elifakwe uketshezi lwe-ester linikeza amandla e-dielectric afinyelela ku-300 kV BIL, afanelekela kakhulu izindawo ezincane ezinama-voltage aphezulu.
    Imelana nokujikeleza kokushisa (−40°C kuya ku-+140°C) kanye nokukhishwa kwengxenye.
    I-Epoxy Resin Casting (Uhlobo Olomile):
    Ukufakwa kwe-vacuum-pressure impregnation (VPI) ngama-epoxy resins ekilasini H kuqinisekisa ukumelana nomlilo (IEC 60335) kanye nokubekezelela umswakama ezindaweni ezivaliwe.
    Ukufakwa Kokushisa Okuthuthukisiwe Kwe-Nano:
    Izinhlanganisela ze-epoxy ezigcwele i-silica zithuthukisa ukumelana nokukhishwa kwegesi okungaphelele ngo-40%, zandisa isikhathi sokuphila ezindaweni zasemadolobheni ezinomswakama noma ezingcolile.
    3. Ukuphathwa Kokushisa​
    Ukupholisa Umoya Okwenziwa Ngowoyela-Okwemvelo (i-ONAN):
    Ukupholisa okungenamsebenzi ngama-radiator kanye ne-convection yemvelo yokusebenza okuqhubekayo ezindaweni ezincane (isb., amayunithi angu-100kVA–500kVA).
    Ukupholisa Umoya Ophoqelelwe (OFAF):
    Amafeni alawulwa amazinga okushisa athuthukisa ukushabalaliswa kokushisa, okwenza kube namandla okulayisha ngokweqile angu-120% ezimweni eziphuthumayo.
    Ukuqapha Okuhlakaniphile Kokushisa:
    Izinzwa ze-fiber-optic zilandelela izindawo ezishisayo, zibangele ama-alamu noma ukulungiswa kokupholisa ukuze kuvinjelwe ukonakala kokufakwa kokushisa.
    4. Umklamo Nokuvikelwa Kwesakhiwo​
    Isakhiwo Esilungiselelwe Ngokumamojuli Nesikhala​
    Izindawo Ezihlanganisiwe:
    Izivalo ezakhiwe kusengaphambili, ezihlanganisiwe, zigcina ama-transformer, ama-switchgear, kanye nezinhlelo zokuvikela endaweni eyodwa, okunciphisa isikhathi sokufakwa ngo-50%.
    Izilinganiso ze-IP66/IP67:
    Ukuvalwa kwe-hermetic ngama-gasket e-EPDM kanye nezinsimbi zensimbi engagqwali kuvikela emanzini, uthuli kanye nokungena kwamagundane.
    Ukwelashwa Kokulwa Nokugqwala:
    Izivalo zensimbi ezicwebezelayo noma ze-aluminium ezicwiliswa ngokushisa ezine-polyurethane coating zimelana nokuwohloka kwe-UV kanye nokuchayeka kusawoti wasogwini.
    Izici Zokuphepha
    Ama-Valve Okunciphisa Ukucindezeleka:
    Ikhipha amagesi ngokuzenzakalelayo ngesikhathi sokuphuka kwangaphakathi, ivimbela ukwehluleka kokuqhuma.
    Izinhlelo zeTanki Lomlondolozi:
    Ama-conservator avalwe nge-vacuum anciphisa ukuthintana nomoya-mpilo, anciphisa ukuminyana kwamafutha kanye nokwakheka kodaka.
    Ukuvikelwa Kokukhuphuka:
    Ama-Integrated zinc oxide arresters (MOA) acindezela ama-transients abangelwa umbani (≥2.5 kA impulses).
    5. Imisebenzi Ethuthukisiwe​
    Izinhlelo Zokuqapha Isimo (i-CMS):
    Izinzwa ezifakiwe zilandelela izinga lokushisa likawoyela, ukuhlaziywa kwegesi encibilikisiwe (i-DGA), amazinga omthwalo, kanye nokukhishwa kwengxenye, okuvumela ukulungiswa okubikezelayo nge-SCADA.
    Ukuhlanganiswa kwe-Smart Grid:
    Ukuxhumana okunikwe amandla yi-IoT kusekela ukulawula okukude, ukulinganisela umthwalo, kanye nezimpendulo zegridi eziziphilisayo.
    Izinto Ezintsha Ezingachemi Imvelo:
    Amafutha okuvikela asekelwe ku-bio (isb., uketshezi lwe-ester) anokubola okuphezulu (okuhambisana ne-OECD 301B) kanye nokusha okuncane.
    Izicelo Eziyinhloko kanye Nezindlela Zesikhathi Esizayo​
    Ukusatshalaliswa Kwasemadolobheni:
    Iziteshi zamandla zedolobha ezinamayunithi aphezulu (500kVA–1 MVA), ama-microgrid avuselelekayo, kanye neziteshi zokushaja ze-EV.
    Ukuhlanganiswa Kwamandla Avuselelekayo:
    Imiklamo emincane yamapulazi omoya/elanga kanye nama-microgrid e-AC/DC ahlanganisiwe.
    Intuthuko Yesikhathi Esizayo:
    Ama-Transformers e-Solid-State (ama-SST): Nika amandla ukuguqulwa kwe-DC-DC kanye nokuguquguquka kwegridi kwezinhlelo ezihlukaniswe ngokwezigaba.
    Ukuzivikela Okuziphilisayo: Izinto ze-nanocomposite zilungisa ngokuzimela amaphutha amancane e-dielectric.
    Isifinyezo
    Iziteshi ezincane zisebenza kahle kakhulu ngokusebenzisa ama-core angenawo ukwakheka okuphansi, imiklamo ye-modular egcina isikhala, kanye nezinhlelo zokuphepha ezinezingqimba eziningi. Ukuhlanganiswa kwazo kokusebenza kahle, ukuguquguquka, kanye nokuqina kuzenza zibe yinto ebalulekile kumagridi anamuhla asemadolobheni nasezimbonini, kuyilapho izinto ezintsha ezifana nobuchwepheshe obuqinile kanye nokuqapha okuhlakaniphile kuqhuba ubuhlakani begridi kanye nokusimama.
    I-Transformer Ecwiliswe Kuwoyela we-Cooper06I-Transformer Ecwiliswe Kuwoyela we-Cooper07I-Transformer Ecwiliswe Kuwoyela we-Cooper08I-Transformer Ecwiliswe Kuwoyela we-Cooper09

    Buza Manje!

    Uma unemibuzo mayelana nemikhiqizo yethu noma uhlu lwamanani, sicela usishiyele i-imeyili yakho futhi sizoxhumana nathi zingakapheli amahora angama-24.

    Leave Your Message