Ama-transformer e-JZP Transformer angu-2000kVA, angu-34.5kV afakwe kuma-pad afakwa ku-Battery Energy Storage System (BESS) eKern County, eCalifornia, lapho enikeza khona amandla asekelayo athembekile ukusekela imishini ehlukahlukene ngaphakathi kwesiteshi sokugcina amandla. Njengoba aqediwe ngoMeyi 2024 futhi alethwa kumakhasimende aseMelika, lawa ma-transformer abalulekile ekuqinisekiseni ukusebenza okungaphazanyiswa kanye nokuphathwa kahle kokugcinwa kwamandla.
01020304050607
| Amazinga okushisa azungezile | Ubuncane -15.0°C, Ubuningi obungu-41.0°C, isilinganiso esiphezulu samahora angu-24 esingu-33.0°C |
| Ukuphakama | |
| Izimo zokuzamazama komhlaba: | Isigaba Sengozi: II, Isigaba Sendawo D |
| I-SS = 1.28 g, i-S1 = 0.43 g, i-SMS = 1.54 g, i-SM1 = 1.09 g, i-SDS = 1.03 g, i-SD1 = 0.73 g |
| Ukusebenza okujwayelekile (isigaba kuya kwesigaba) | 34.5kV |
| Ukusebenza okuphezulu (isigaba kuya kwesigaba) | 38kV |
| Ukucushwa kokugoqa | I-Delta |
| Isilinganiso se-Bushing | 600A |
| Ukufakwa komoya okuvala umoya | 200kV BIL |
| Ukufakwa kwe-bushing | 200kV BIL |
| Ubuningi be-Bushing | Isithupha (I-Loop Feed) |
| Ukumelana nesekhethi esifushane | 30kA |
| Nqamula uxhumano | I-LBOR Switch |
| Nqamula inani lokushintsha | Isigaba Esisodwa (1) 3 |
| Ukusebenza okujwayelekile (isigaba kuya kwesigaba) | 480V |
| Ukucushwa kokugoqa | I-Wye Ephansi |
| Ukufakwa kwe-BIL kokuvikela nokubopha | IMOTO ENGU-30KV |
| Ukumelana ne-short-circuit | 65 kA* |
| Ubuningi bembobo ye-LV bushing spade | (8) AKUKHO migodi emibili |
| Isici sokweqisa kwamandla kagesi okuvamile | 110% |
| Ukumelana okuqinile | Cha |
| Ibhasi elihamba phansi | Yebo |
| I-voltage yokunikezela ngesekethe yokulawula | I-AC engu-277V |
| Imininingwane ye-circuit breaker | I-UL ibhalwe ohlwini |
| Ilungele ukungena kwesevisi | Yebo |
| Ubukhulu (ngaphakathi) | Ububanzi: 83.9*94.7*95.3 |
| Ithangi Nezesekeli | 4,630lbs |
| Uwoyela womthamo | 900Gal |
| Isisindo Esiphelele | 21,600lbs |
Izici Eziyinhloko Nezinzuzo
Ukusatshalaliswa Kwamandla Okusebenzayo Kwesitoreji Samandla
Ama-transformer angu-2000kVA aklanyelwe ukwehla kusuka ku-Medium Voltage (MV) kuya ku-Low Voltage (LV), okwenza abe ngcono kakhulu ekuhlanganisweni nama-switchboard ezinhlelweni zokugcina amandla. Lokhu kulungiselelwa kokwehla kubalulekile ekuqinisekiseni ukusatshalaliswa kwamandla okubushelelezi nokuthembekile emishinini yokusiza, okusekela ukusebenza kahle kwengqalasizinda ye-BESS.
Ukupholisa Okusimeme Futhi Okungabizi Kakhulu
Ngokuvumelana nokuzibophezela kwe-JZP Transformer ekusimeni, ama-transformer asebenzisa uwoyela obolayo njengoketshezi olupholisa. Lesi sixazululo esinobungani nemvelo asigcini nje ngokunikeza izakhiwo zokuvikela ezisezingeni eliphezulu kodwa futhi sisekela nokusebenza kahle kwamandla.
Ukuqina Nokuphepha Okwakhelwe Ngaphakathi
Izivalo ze-NEMA 3R: Ama-transformer ethu agcinwe ezivalo zikagesi ezilinganiselwe yi-NEMA 3R ezingangeni emvuleni, ezingangeni eqhweni, futhi ezingangeni eqhweni, ezinezindawo zokukhipha amanzi ezakhiwe ngaphakathi. Lezi zivalo zinikeza isivikelo esiqinile ezimweni zezulu, zivikela izingxenye zikagesi zangaphakathi futhi ziqinisekisa ukuqina kwesikhathi eside ngisho nasezimweni zemvelo ezinzima.
Izici Zokulwa Nokuphazanyiswa Nokuphepha: Njengoba zaklanywa kucatshangelwa ukuphepha, ama-transformer anezindlela zokukhiya nokubopha ezihlukile ukuvimbela ukufinyelela okungagunyaziwe nokuphazanyiswa, ukunciphisa ingozi yokwebiwa nokuqinisekisa ukusebenza okuphephile ngaso sonke isikhathi.
Idizayini Elula Ukusetshenziswa Kokuphepha Nokusebenza Kahle
Uhlangothi olune-voltage ephansi lwe-transformer lunomklamo okhethekile ofakwe eceleni onomphimbo wokuxhuma kalula ebhodini lokushintsha. Ama-gauge afakwe ngaphandle, ama-valve esampula, kanye nezinhlelo zokukhipha amanzi zigcinwe ekhabetheni elikhiywayo elinokhiye we-bolt onamaphuzu amahlanu. Lo mklamo oyingqayizivele uvumela abaqhubi ukuthi bahlole amazinga kawoyela ngokuphephile, bahlole ama-gauge, futhi benze imisebenzi yokulungisa ngaphandle kokuzibeka ezihlahleni ze-voltage ephezulu (HV) noma ze-voltage ephansi (LV), okuthuthukisa kakhulu ukuphepha nokusebenza kahle.

Amageyiji angaphandle e-transformer afakwe ephedi
Ukuqapha Okuthuthukisiwe Nezaziso Ezikude
Ukuqinisekisa ukusebenza okuqhubekayo nokuhle kakhulu, i-transformer ifakwe izinkomba zezinga likawoyela kanye nokushisa ezibonisa izindawo ezimbili zokuxhumana zokuqapha kude. Lezi zinkomba zinikeza idatha yesikhathi sangempela kubasebenzi, zithumela izimpawu ze-alamu lapho izinga likawoyela liphezulu kakhulu noma liphansi kakhulu. Ngaphezu kwalokho, uma izinga lokushisa loketshezi olupholile lidlula u-85°C, uhlelo luzoqala i-alamu. Uma izinga lokushisa likhuphuka ngaphezu kuka-105°C, i-transformer izonqamula ngokuzenzakalelayo kugridi ukuze ivimbele ukushisa ngokweqile kanye nomonakalo ongaba khona, iqinisekise ukuphepha nokuthembeka kohlelo.

Ikhwalithi Nokuhambisana Nemithetho
Ama-JZP Transformers akhiqizwa ngokuhambisana ngokuqinile nezindinganiso ezihamba phambili embonini, okuhlanganisa i-UL, i-ANSI, i-IEEE, ne-NEMA, okuqinisekisa ukusebenza okuphezulu, ukuthembeka, kanye nokuphepha. Ukuzibophezela kwethu ekhwalithini nasekusunguleni izinto ezintsha kuqinisekisa ukuthi i-transformer ngayinye yakhelwe ngokwezidingo eziphezulu, inikeza isevisi ethembekile kuyo yonke impilo yemishini.

Buza Manje!
Uma unemibuzo mayelana nemikhiqizo yethu noma uhlu lwamanani, sicela usishiyele i-imeyili yakho futhi sizoxhumana nathi zingakapheli amahora angama-24.