Leave Your Message

I-Transformer Efakwe I-Pole Yesigaba Esisodwa—15KVA

Izilinganiso Eziyinhloko Ze-Voltage: 12470 Delta V
Izilinganiso Ze-Voltage Yesibili: 120/240V
UBANGA LOKUTHEPHA KWE-HV: ±2*2.5%
UHLOBO LOKUXHUMANA: Ii6
UHLOBO: I-transformer efakwe ensikeni
KWAKUYI: 95/30kV
Amazinga: I-IEEE C57.12.20, i-ANSI C57.12
Isicelo: Ubuningi kanye nokusatshalaliswa

    Incazelo Yomkhiqizo

    I-JZP Transformer igxile ekukhiqizeni ama-transformer angu-15 kVA afakwe ezigxotsheni ezinesigaba esisodwa ahambisana ngokuqinile nezindinganiso zomhlaba wonke ezihamba phambili, okuhlanganisa i-IEEE C57.12.00, i-IEEE C57.12.20, i-DOE-2016 Efficiency Requirements, i-CSA C2.1 kanye ne-C2.2, kanye ne-CSA C802.1. Siqhutshwa ukuzibophezela okungapheli ekwenzeni kahle, sinikeza izixazululo ezenzelwe wena eziklanyelwe ukuhambisana kahle nemininingwane yakho yobuchwepheshe ehlukile.
    Kungakhathaliseki ukuthi izinga le-voltage noma indawo yokusebenza oyidingayo, thembela i-JZP Transformer ukuthi ikunikeze ikhambi elifanele elifanela izidingo zakho ezithile. Ukwaneliseka kwakho, okuhlangene nokuthembeka okungapheli kwama-transformer ethu, kuhlala kuyitshe lesisekelo sokuzinikela kwethu ekuletheni ikhwalithi evelele.
    Ukuze siqinisekise inqubo yokulethwa ebushelelezi nengabizi kakhulu, sihlele futhi sapakisha wonke ama-transformer ngokucophelela ukuze angene kahle esitsheni esisodwa esingu-40HQ, senza kube lula ukuthutha futhi sinciphise izindleko zokuhamba zizonke.
    Ngokukhetha ama-transformer e-JZP, ikhasimende lingaqiniseka ngesinqumo salo sokutshala imali emishinini kagesi esezingeni eliphezulu, okuthembisa ukusebenza okungenakuqhathaniswa nokonga amandla. Lokhu kuzibophezela ekusebenzeni kahle nasekuzinzeni kuhambisana nomsebenzi wethu wokufaka isandla endaweni yamandla eluhlaza futhi enomthwalo wemfanelo.
    I-Transformer Efakwe Ngezinsika engu-15kVA engu-21.6kV
    Sethula i-DL-15/21.6/0.24(0.12), i-transformer esezingeni eliphezulu engu-15 kVA enesigaba esisodwa efakwe izigxobo eklanywe ngokucophelela futhi yakhiqizwa ngokuziqhenya yi-JZP Transformer. Le transformer ihlangabezana nezindinganiso eziqinile ze-IEEE Std C57.12.00 kanye ne-IEEE Std C57.12.20, okuqinisekisa ukusebenza kahle nokuphepha okuhle kakhulu.
    Ngesilinganiso se-voltage esiphezulu esingu-21.6 kV kanye nesilinganiso se-voltage esiphansi esingu-240V (120V), i-DL-15/21.6/0.24(0.12) iguqula amandla ngempumelelo ukuze ihambisane nezinhlelo zokusebenza ezahlukahlukene. Ukulawulwa kwayo okubanzi kwe-voltage kusuka ku-21600V kuya ku-22680V kuqinisekisa ukuphuma kwe-voltage okuqhubekayo nokuzinzile, okuvumela ukusebenza okuthembekile ngisho nangaphansi kwemithwalo eguquguqukayo.
    Ukuze inikeze ukuvikelwa okuqinile kanye nokuvikelwa, i-transformer ine-BIL (Basic Insulation Level) engu-125 kV ye-voltage ephezulu kanye ne-30 kV ye-voltage ephansi, ivikela ekukhuphukeni kukagesi futhi iqinisekise ukuqina okuhlala isikhathi eside.
    15kVA 21
    I-Transformer Efakwe Ngezinsika engu-15kVA engu-14.4kV
    Sethula i-JZP-15/14.4(24.94)/0.24(0.12), i-transformer engu-15 kVA efakwe esigxotsheni esisodwa eklanywe futhi yakhiqizwa ngokuziqhenya yi-JZP Transformer.
    Inamandla aphezulu angu-14.4 kV kanye ne-voltage ephansi engu-240V (120V), isilinganiso samandla angu-15 kVA. I-DL-15/14.4(24.94)/0.24(0.12) iqinisekisa ukuguqulwa kwamandla okusebenzayo nokuthembekile ukuze kuhlangatshezwane nezidingo zamandla ahlukahlukene. Ama-windings aphezulu naphansi e-voltage akhiwe nge-aluminium eqinile, okuqinisekisa ukusebenza okuphezulu kanye nobude besikhathi.
    I-transformer yakhelwe nge-polarity eyengeziwe, eqinisekisa ukuhambisana okungenamthungo kanye nokusebenza okuthuthukisiwe ohlelweni lwakho lokusabalalisa amandla.
    Njengoba inobubanzi bokulawula i-voltage obusukela ku-13680V kuya ku-15120V, le transformer iqinisekisa ukuphuma kwe-voltage okuzinzile nokungaguquguquki, iletha ukusebenza okuhle ngaphansi kwezimo zomthwalo ezahlukahlukene. I-BIL yayo emangalisayo (Izinga Lokufaka Eliyisisekelo) elingu-95 kV kanye no-30 kV iqinisekisa ukuvikelwa okuqinile ekukhuphukeni kukagesi, okuthuthukisa ukuthembeka nokuphepha kwe-transformer.
    15kVA 14
    I-Transformer Efakwe Ngezinsika engu-15kVA engu-14.4kV
    Uketshezi oluvikela ukushisa olusetshenziswayo luyi-oyili yamaminerali esezingeni eliphezulu, alunayo i-PCB, olukhuthaza ukusebenza okuphephile nokunobungani nemvelo. Uhlelo lokupholisa lusebenzisa indlela ye-ONAN (Oil Natural Air Natural), luqeda ukushisa ngempumelelo futhi lugcine ukusebenza kahle kwe-transformer.
    Ngaphezu kwalokho, i-transformer engu-15kVA engu-14.4 kV ifika ifakwe ama-bushing amabili ane-voltage ephezulu kanye nama-bushing amathathu ane-voltage ephansi, enikeza izinketho zokuxhuma eziguquguqukayo. Ama-bushing ane-voltage ephansi ahambisana nemigoqo yethusi ephansi, okuqinisekisa ukuphepha okuthuthukisiwe ngesikhathi sokusebenza.
    Ezisetshenzisweni zezigaba ezintathu, ama-transformer amathathu angu-14.4 kV afakwe izigxobo zesigaba esisodwa angahlanganiswa ngempumelelo ukuze alethe amandla angu-24.94 kV, ahlangabezane nezidingo zezinhlelo ezahlukene zezimboni kanye nezinsiza.
    Umbiko Wokuhlola Wesiguquli Esifakwe Ipole Eliyi-10kVA 6
    I-Transformer Efakwe Ngezinsika engu-15kVA engu-7.2kV
    Kwethulwa i-DL-15/7.2(12.47)/0.24(0.12), iyi-transformer efakwe esigxotsheni esisodwa eklanywe futhi yakhiqizwa yi-JZPTransformer. Le transformer inamandla aqinile angu-15 kVA, okwenza ifaneleke kakhulu ekusetshenzisweni okuhlukahlukene. Ngesilinganiso se-voltage esiyinhloko esingu-7.2 kV (12.47 kV) kanye nesilinganiso se-voltage sesibili esingu-120V (240V), le transformer iqinisekisa ukuguqulwa kwe-voltage okuphumelelayo ukuze kuhlangatshezwane nezidingo zamandla ahlukahlukene.
    Ukuze kuhlangatshezwane nokuxhumeka okuhlukene kanye nezinhlelo zokusebenza, i-DL-15/7.2(12.47)/0.24(0.12) iza ifakwe ama-bushing amabili ane-voltage ephezulu kanye nama-bushing amathathu ane-voltage ephansi, anemiklamo yokusekela ene-voltage ephansi yokuphepha okuthuthukisiwe.
    Njengoba inebanga elimangalisayo lokulawula i-voltage yesigaba eliqala ku-6840V kuya ku-7560V, le transformer iqinisekisa ukulawulwa kwe-voltage okuthembekile nokungaguquguquki, okuqinisekisa ukusatshalaliswa kwamandla okuzinzile emithwalweni ehlukahlukene. Ngaphezu kwalokho, i-DL-15/7.2(12.47)/0.24(0.12) ibonisa ukuguquguquka, njengoba ama-transformer amathathu esigaba esisodwa alo mklamo angaxhunywa kalula ukuze akhe i-transformer yesigaba sesithathu engu-12.47 kV, ehlangabezana nezinhlelo zokusebenza eziningi zezimboni kanye nezinsiza.
    Umbiko Wokuhlola Wesiguquli Esifakwe Ipole Eliyi-10kVA 6
    I-Transformer Efakwe Ngezinsika engu-15kVA engu-19.2kV
    I-DL-25/19.92/0.24(0.12), iyi-transformer evelele engu-15 kVA enesigaba esisodwa, eyenziwe ngokuziqhenya yi-JZP Transformer, futhi inamathela ezindinganisweni eziqinile ze-IEEE C57.12.20 kanye ne-ANSI C57.12. Le transformer yenzelwe ukuletha ukusebenza okuphezulu nokuthembeka, ihlangabezana nezidingo ezahlukahlukene zezinhlelo zanamuhla zokusabalalisa amandla. I-transformer engu-15kVA ifaka i-depolarization futhi isebenzisa iqembu le-Iio vector, iqinisekisa ukuhamba kwamandla okusebenzayo nokungenamthungo, futhi ithuthukisa ukusebenza kanye nokuzinza kwenethiwekhi yokusabalalisa.
    Umbiko Wokuhlola Wesiguquli Esifakwe Ipole Eliyi-10kVA 6
    Umbiko Wokuhlola Wesiguquli Esifakwe Ipole Eliyi-10kVA
    Kwa-JZP Transformer, ikhwalithi ihamba phambili enqubweni yethu yokukhiqiza. I-transformer ngayinye efakwe esigxotsheni esisodwa idlula ekuhlolweni okunzima nokubanzi okuvamile ngaphambi kokuba isuke efektri yethu. Silandela imigomo yokulawula ikhwalithi eqinile ukuqinisekisa ukuthi i-transformer ngayinye ihlangabezana nezindinganiso eziphakeme kakhulu embonini futhi idlula okulindelwe amakhasimende.
    Ngesikhathi sokuhlolwa okuvamile, ochwepheshe bethu abanekhono bahlola ngokucophelela futhi bahlole ukusebenza kwe-transformer, ukuphepha kwayo, kanye nokuthembeka kwayo. Amapharamitha abalulekile njengokulawulwa kwamandla kagesi, ukumelana nokushisa, ukulahlekelwa umthwalo, ukulahlekelwa umthwalo, kanye nokungavimbeli kuhlolwa ngokucophelela ukuqinisekisa ukusebenza kahle kwe-transformer.
    Kuphela ngemva kokuphumelela ngempumelelo ukuhlolwa okuvamile okuqinile nokuhlangabezana nazo zonke izindinganiso zekhwalithi, i-transformer ibhekwa njengefanelekile ukupakishwa nokuthunyelwa. Le ndlela ecophelelayo iqinisekisa ukuthi amakhasimende ethu athola kuphela ama-transformer amahle kakhulu nathembekile ahambisana kahle nezidingo zawo ezithile.
    Umbiko Wokuhlola Wesiguquli Esifakwe Ipole Eliyi-10kVA 6

    Buza Manje!

    Uma unemibuzo mayelana nemikhiqizo yethu noma uhlu lwamanani, sicela usishiyele i-imeyili yakho futhi sizoxhumana nathi zingakapheli amahora angama-24.

    Leave Your Message