+86 18068001229 01
Ama-Transformer Ohlobo Olomile Asebenza Kakhulu
Izici Eziyinhloko Nezinzuzo
Idizayini Engashisi Futhi Enobungani Nemvelo
Njengoba kungekho uwoyela ovuthayo, ama-transformer ohlobo olomile ahlangabezana nezindinganiso zokuphepha emlilweni eziqinile (IEC 61558) futhi afanelekela izibhedlela, izikhungo zedatha, kanye nezakhiwo zokuhlala. Izinto ezingasetshenziswa kabusha kanye nokungavuzi uwoyela kuqinisekisa ukuhambisana nemvelo.
.Ukusebenza Kahle Kakhulu Nokonga Amandla
Izinto eziyinhloko ezithuthukisiwe (i-alloy engaguquki noma insimbi ye-silicon) kanye nemiklamo yokugoqa eyenziwe kahle kunciphisa ukulahlekelwa kwamandla ngamaphesenti afinyelela ku-30, kufinyelela amazinga okusebenza kahle ≥98% (iqinisekiswe yi-IEC 61378). Ifanele ukusebenza okuqhubekayo ngokukhiqiza ukushisa okuncane.
.Ukugcinwa Okuphansi Nokuphila Isikhathi Eside
Izinhlelo zokuvikela eziqinile ziyamelana nomswakama, uthuli, kanye nokungcola kwamakhemikhali, okunciphisa izidingo zokulungisa. Ukwakhiwa okuqinile kumelana nezimo ezinzima, kwandisa isikhathi senkonzo ezindaweni zezimboni noma zasogwini.
.Incane futhi Yonga Isikhala
Imiklamo ye-Modular kanye nezinyathelo ezincane zenza kube lula ukufakwa eziteshini ezincane zasemadolobheni, ezakhiweni zezentengiselwano, noma ezindaweni zamandla avuselelekayo. Itholakala ngama-voltage asukela ku-380V kuya ku-36kV kanye namandla afinyelela ku-5 MVA.
.Ukuqapha Okuhlakaniphile Nokuphepha
Izinzwa ze-IoT ezingakhethwa ziqapha izinga lokushisa, i-voltage, kanye nomthwalo ngesikhathi sangempela, okuvumela ukulungiswa kokubikezela. Izinhlelo zokuvikela ezakhelwe ngaphakathi (isb., ama-thermal relay, ama-alamu e-Buchholz) zivimbela amaphutha futhi ziqinisekisa ukusebenza okuphephile.




Izicelo
Ingqalasizinda Yasemadolobheni: Ukusatshalaliswa kwamandla okuphephile ezindaweni ezinabantu abaningi, ezitolo ezinkulu, kanye nasezinhlelweni zesitimela esingaphansi komhlaba.
Ukusetshenziswa Kwezimboni: Ukutholakala okuzinzile kwezimboni zokukhiqiza, imisebenzi yezimayini, kanye nezimboni zamakhemikhali.
.Amandla Avuselelekayo: Ukuhlanganiswa namapulazi elanga/omoya ukuze kuxhunywe kahle igridi.
.Izakhiwo Zezentengiselwano: Izinhlelo ze-HVAC, ama-lifti, kanye namanethiwekhi okukhanyisa.
Imininingwane Yobuchwepheshe
Ibanga Le-Voltage: 380V kuya ku-36kV (i-voltage ephakathi nendawo).
.Umthamo: 50 kVA kuya ku-5,000 kVA.
.Izinhlobo Zokupholisa: I-Air Natural (AN) noma i-Air Forced (AF).
.Ikilasi Lokufaka Izinto Ezivikela Ukushisa: I-H-class (180°C) yokumelana nokushisa okuphezulu.
.Imvamisa: 50Hz/60Hz.
Ukuqinisekisa ikhwalithi
Ukuhlolwa okuqinile kufaka phakathi i-implitude voltage, ukulahlekelwa umthwalo, kanye nokulingisa ukuphakama kwezinga lokushisa.
Kuqinisekiswe yi-IEC, i-IEEE, i-ISO 9001 (ikhwalithi), kanye ne-ISO 14001 (imvelo).
Kungani Kufanele Ukhethe Thina?
Iminyaka Engu-30+ Yobuchwepheshe: Imiklamo eqinisekisiwe yokushisa okukhulu, umswakama, kanye nezindawo zokuzamazama komhlaba.
.Ukusekelwa Komhlaba Wonke: Amaqembu obunjiniyela bendawo kanye nosizo lobuchwepheshe olusebenza amahora angama-24 ngosuku, izinsuku eziyi-7 ngesonto.
.Izixazululo Ezingabizi Kakhulu: Imiklamo ekwazi ukwandiswa enezinketho zezimali eziguquguqukayo.
Izixazululo Zenziwe Ngokwezifiso
Amamodeli Amelana Nomlilo Futhi Angaqhumi: Kwezindawo zikawoyela/igesi noma izindawo eziyingozi.
.Imiklamo Enobungani Nemvelo: Umsindo ophansi (
.Izinhlelo Ezihlanganisiwe: Kuhlanganiswe nesitoreji samandla sezinhlelo zokusebenza zegridi ehlakaniphile.



Izinzuzo zomkhiqizo
1. Izinto Eziyinhloko kanye Nomklamo Wokugoba
Izinto Eziyinhloko
Ama-Cores e-Amorphous Alloy:
Ukulahleka kwensimbi okuphansi kakhulu (okungaphansi ngo-70–80% kunensimbi ye-silicon yendabuko), kunciphisa ukuchithwa kwamandla kanye nezindleko zokusebenza.
Ukungena okuphezulu kanye nokunciphisa amandla kagesi okufinyelela ku-zero kunciphisa umsindo nokudlidliza, okulungele izindawo zokuhlala nezebhizinisi.
Insimbi Ye-Silicon Eqondiswe Kuma-Grain (CRGO) Ebandayo:
Ama-lamination asikwe nge-laser noma ahlanganiswe ngezinyathelo anciphisa ukulahlekelwa kwamanje kwe-eddy, afinyelele amazinga okusebenza kahle afinyelela ku-98% (izindinganiso ze-IEC 60076).
Ukuqondiswa kokusanhlamvu okulungiselelwe kuthuthukisa ukuminyana kwe-magnetic flux kwezicelo ze-high-voltage (kufika ku-33kV).
Umklamo Wokugoba
Amawindi e-Foil ane-Resin Impregnation:
Ama-winding e-copper noma e-aluminium foil anciphisa ukuvuza komoya kanye namandla okujikeleza okufushane. I-Epoxy resin encapsulation ithuthukisa amandla omshini kanye nokuqhuba ukushisa.
Izendlalelo ezihlanganisiwe zinciphisa ukucindezeleka kwamandla kagesi aphakathi kwamajika, zithuthukisa ukuqina kwe-short-circuit (kufika kumaphutha angalingani angama-50 kA).
Amawindingi e-Litz Wire anezingqimba:
Intambo ye-Litz enezintambo eziningi inciphisa imiphumela yesikhumba kanye nokusondela, inciphisa ukumelana kwe-AC ezisetshenzisweni ezivame kakhulu (isb., abaguquli be-HVDC).
Ukufuthwa kwe-Vacuum-Pressure (VPI):
Amakhoyili afakwe ama-resin epoxy noma e-polyester anokushisa okuphezulu, okuqinisekisa ukumelana nomswakama kanye namandla e-dielectric afinyelela ku-200 kV BIL.
2. Izinhlelo Zokuvikela
Ukukhishwa kwe-Epoxy Resin:
Ukufakwa kokushisa okuqinile ngama-resin epoxy ekilasini H kunikeza ukumelana nomlilo (kuqinisekiswe yi-UL94 V-0) futhi kumelana nokujikeleza kokushisa (−40°C kuya ku-+155°C).
Ukumelana okuphezulu kokukhipha okuyingxenye, okulungele izindawo ezingcolile noma ezinomswakama.
I-Nomex Paper Composite:
Ukufakwa kwe-Aramid fiber kunikeza ukuzinza okuphezulu kokushisa (kufika ku-220°C) kanye namandla e-dielectric, kuhlanganiswe nezakhiwo ezivimbela ilangabi.
Ukufakwa Kokushisa Okuthuthukisiwe Kwe-Nano:
Izinhlanganisela ze-epoxy ezigcwele i-silica zithuthukisa impilo yokukhishwa kwengxenye ngo-40%, zandisa impilo yenkonzo ezimweni ezinzima.
3. Ukuphathwa Kokushisa
Ukupholisa Komoya-Kwemvelo (AN):
Ukupholisa okungenamsebenzi ngama-radiator anezinti noma ama-heat sink okusebenza okuqhubekayo emithwalweni elinganisiwe (isb., amayunithi angu-500kVA–1.5MVA).
Ukupholisa Umoya Ophoqelelwe (AF):
Amafeni alawulwa amazinga okushisa athuthukisa ukushabalaliswa kokushisa, okwenza kube nomthamo wokulayisha ngokweqile ongu-120–150% ezimweni eziphuthumayo.
Ukuqapha Okuhlakaniphile Kokushisa:
Izinzwa zokushisa ezifakiwe kanye nezinhlelo ze-IoT ziqala ama-alamu noma ukulungiswa kokupholisa ukuvimbela ukushisa ngokweqile kanye nokuwohloka kokushisa.
4. Umklamo Nokuvikelwa Kwesakhiwo
Umklamo Ohlanganisiwe Nowokuncane
Izindawo Zokuvala Ezingenamoya:
Izivalo ezinesilinganiso se-IP66/IP67 ezinama-gasket e-EPDM zivikela uthuli, amanzi, kanye nokungena kwamagundane, ezifanele izindawo zangaphandle noma zezimboni.
Izembozo Ezilwa Nokugqwala:
Izivalo zensimbi ezifakwe ngogesi noma ze-aluminium ezishisayo ezine-polyurethane/impuphu zimelana nokuwohloka kwe-UV kanye nokuchayeka kusawoti wasogwini.
Izinto Ezingamelani Nomlilo:
Izinhlelo zokuvikela ukushisa ezingashi kanye nezinhlelo ze-resin ezizicimayo zihlangabezana nezindinganiso zokuphepha emlilweni ze-IEC 60335.
Izici Zokuphepha
Izinhlelo Zokusiza Ukucindezeleka:
Iminyango yokukhulula ukucindezeleka ngokuzenzakalelayo ivimbela ukwehluleka kokuqhuma ngesikhathi sokuphazamiseka kwangaphakathi.
Ukuvikelwa Kokukhuphuka:
Ama-Integrated metal oxide arresters (MOA) acindezela ama-transients abangelwa umbani (≥2.5 kA impulses).
Ukuvimbela Ukusikwa Nokuchitheka:
Izinhlelo zokuqinisa umhlabathi kanye nemiklamo evaliwe kususa izingozi zokuvuza kukawoyela, okuqinisekisa ukuthi akukho ukungcoliswa kwemvelo.
5. Ukusebenza Okuthuthukisiwe
Izinhlelo Zokuqapha Isimo (i-CMS):
Izinzwa ezifakiwe zilandelela izinga lokushisa lokugoba, ukukhishwa okuyingxenye, kanye namazinga omthwalo, okuvumela ukulungiswa kokubikezela ngamapulatifomu e-SCADA noma e-IoT.
Ukuhlanganiswa kwe-Smart Grid:
Ukuxhumana okunikwe amandla yi-IoT kusekela ukuqapha okude, ukulinganisela umthwalo, kanye nezimpendulo zegridi zokuziphilisa.
Izinto Ezintsha Ezingachemi Imvelo:
Ama-resin okuvikela asekelwe ku-bio kanye nezingxenye ze-polymer ezingaphinde zisetshenziswe zihambisana nemigomo yokusimama (isb., ukuhambisana ne-RoHS kanye ne-REACH).
Izicelo Eziyinhloko kanye Nezindlela Zesikhathi Esizayo
Ukusatshalaliswa Kwasemadolobheni Nakwezentengiselwano:
Amadolobha kagesi anamandla amakhulu (500kVA–2 MVA), izikhungo zedatha, kanye neziteshi zokushaja ze-EV.
Amandla Ezimboni Navuselelekayo:
Ilungele iziteshi ezincane zepulazi lelanga/lomoya, izindawo zokumba, kanye nezindawo eziyingozi (iZone 2/22).
Intuthuko Yesikhathi Esizayo:
Ama-Transformers Esifundazwe Esiqinile (ama-SST): Nika amandla ukuguqulwa kwe-DC-DC kanye nokuguquguquka kwegridi kwezinhlelo zamandla ezihlukaniswe ngokwezigaba.
Ama-Nanocomposites Azipholisayo: Izinto ezithuthukisiwe zikhipha ukushisa ngokuzimela ngaphansi kwezimo zamaphutha.
Isifinyezo
Ama-Dry-Type Transformers aphumelela kakhulu ngokusebenzisa ama-core angenawo ukwakheka okuhle, ukuqina kokushisa okuqinile, kanye nokuphathwa kokushisa okuhlakaniphile. Ukuphepha kwawo emlilweni, ukusebenza okungenakulungiswa, kanye nemiklamo enobungani nemvelo kuwenza abe yinto ebalulekile kumagridi anamuhla asemadolobheni nasezimbonini, kuyilapho izinto ezintsha ezifana nobuchwepheshe be-solid-state kanye nokuhlanganiswa kwe-IoT kuqhuba ubuhlakani begridi kanye nokusimama.