+86 18068001229 01
Izinhlelo Zegridi Ezinezigaba Ezintathu Eziqinile Ezicwiliswe Ngowoyela
Izici Eziyinhloko Nezinzuzo
Ukupholisa Nokuqina Okusebenzayo
Ifakwe ku-oyela wokuvikela osezingeni eliphezulu, i-transformer isusa ukushisa ngempumelelo (ukupholisa kwe-ONAN/ONAF), igcina ukusebenza kahle ngisho nangaphansi kwemithwalo esindayo. Uwoyela usebenza futhi njengesivikelo, uthuthukisa ukuphepha kukagesi futhi unciphise ukuguguleka.
.Ukuthembeka Okuphezulu Nokulungiswa Okuphansi
Ukwakhiwa okuqinile okunezimbobo zethusi kanye nezinhlelo zokuvikela uwoyela wephepha ezithuthukisiwe kuqinisekisa ukumelana nokucindezeleka kokushisa, umswakama, kanye nezifunda ezimfushane. Izidingo ezincane zokunakekelwa zenza kube kuhle ezindaweni ezikude noma okunzima ukuzifinyelela.
.Umklamo Ohlanganisiwe Nowe-Modular
Itholakala ngezilinganiso zama-voltage kusukela ku-11kV kuya ku-33kV kanye namandla afinyelela ku-5 MVA, ngokulungiswa kwesigaba esisodwa noma ezintathu. Usayizi omncane wenza kube lula ukufakwa eziteshini zasemadolobheni, emapaki ezimboni, noma kumanethiwekhi asemakhaya.
.Ukuqapha Okuhlakaniphile (Ongakukhetha)
Izinzwa ezisebenzisa i-IoT (ongakukhetha) zinikeza idatha yesikhathi sangempela ngokushisa kukawoyela, amazinga omthwalo, kanye nokutholwa kwamaphutha, okuvumela ukulungiswa kokubikezela kanye nokunciphisa isikhathi sokungasebenzi.
.Kunobungani Nemvelo Futhi Kubiza Kahle
Ukusebenza komsindo ophansi (




Izicelo
Amanethiwekhi Ezindawo Zokuhlala: Ukwehlisa i-voltage ephakathi (11kV/33kV) ibe ngu-230/400V emakhaya.
.Izimboni kanye Nezentengiselwano: Ukunikezwa kwamandla okuzinzile kwezitshalo zokukhiqiza, izikhungo zedatha, kanye nezitolo ezinkulu.
.Ukuhlanganiswa Okuvuselelwayo: Ukuxhumanisa amapulazi elanga/omoya kumagridi ane-voltage ephansi.
.Ukufakwa kukagesi ezindaweni zasemakhaya: Idizayini eqinile yezindawo ezikude noma ezinzima.
Imininingwane Yobuchwepheshe
Ibanga Le-Voltage: 11kV kuya ku-33kV (i-voltage ephakathi nendawo).
.Umthamo: 500 kVA kuya ku-5,000 kVA.
.Imvamisa: 50Hz/60Hz.
.Ukupholisa: I-ONAN (Amafutha Omoya Wemvelo) noma i-ONAF (Amafutha Omoya Wemvelo Ophoqelelwe).
.Ukusebenza kahle: ≥98% uma ilayishiwe ngokugcwele (kuqinisekiswe yi-IEC 61378).
Ukuqinisekisa ikhwalithi
Ukuhlolwa okuqinile kuqinisekisa ukuhambisana nezindinganiso zomhlaba wonke:
Ukuhlolwa kwamandla e-dielectric kokuqina kokuvikela ukushisa.
Ukulahlekelwa umthwalo kanye nokulinganiswa kokwenyuka kwezinga lokushisa.
Ukuqinisekiswa kokumelana ne-short-circuit.
Kuqinisekiswe yi-ISO 9001 (ikhwalithi), i-ISO 14001 (imvelo), kanye ne-KEMA ngokuphepha nokuthembeka.
Kungani Kufanele Ukhethe Thina?
Iminyaka Engu-30+ Yobuchwepheshe: Imiklamo eqinisekisiwe yezimo zezulu nezokusebenza ezahlukahlukene.
.Inethiwekhi Yokusekela Yomhlaba Wonke: Amaqembu enkonzo asendaweni kanye nosizo lobuchwepheshe olusebenza amahora angama-24 ngosuku, izinsuku eziyi-7 ngesonto.
.Amanani Okuncintisana: Izixazululo ezingandiswa ngokwezidingo zesabelomali kanye nokusebenza.
Izixazululo Zenziwe Ngokwezifiso
Imiklamo Ekhethekile: Uma amazinga okushisa aphezulu kakhulu, izindawo ezigqwalisayo, noma izindawo zokuzamazama komhlaba.
.Ukuthuthukiswa Kokusebenzisa Amandla Kahle: Amakhithi okulungisa kabusha izinhlelo ezindala.



Izinzuzo zomkhiqizo
1. Izinto Eziyinhloko kanye Nomklamo Wokugoba
Izinto Eziyinhloko
Ama-Cores e-Amorphous Alloy:
Ukulahleka kwensimbi okuphansi kakhulu (okungaphansi ngo-70–80% kunensimbi ye-silicon yendabuko), kunciphisa ukuchithwa kwamandla kanye nezindleko zokusebenza.
Ukungena kwamanzi okuphezulu kanye nokunciphisa amandla kagesi okusondela ku-zero kunciphisa umsindo nokudlidliza, okulungele izindawo zokuhlala nezimboni.
Insimbi Ye-Silicon Eqondiswe Kuma-Grain (CRGO) Ebandayo:
Ama-lamination asikwe nge-laser noma ahlanganiswe ngezinyathelo anciphisa ukulahlekelwa kwamanje kwe-eddy, afinyelela amazinga okusebenza kahle afinyelela ku-98.5%.
Ukuqondiswa kokusanhlamvu okulungiselelwe kuthuthukisa ukuminyana kwe-magnetic flux kwezicelo ze-high-voltage (isb., 11kV–33kV).
Umklamo Wokugoba
Amawindi e-Foil anokupholisa okugeleza kwamafutha:
Ama-winding e-copper noma e-aluminium foil anciphisa ukuvuza kwamandla kanye namandla okujikeleza okufushane. Ukugeleza kukawoyela ngemibhobho ejikelezayo kuthuthukisa ukushabalaliswa kokushisa.
Izendlalelo zomqhubi ezihlanganisiwe zinciphisa ukucindezeleka kwamandla kagesi aphakathi kwamajika futhi zithuthukise ukuqina kwe-short-circuit.
Amawindingi e-Litz Wire anezingqimba:
Intambo ye-Litz enezintambo eziningi inciphisa imiphumela yesikhumba kanye nokusondela, inciphisa ukumelana ne-AC kanye nokulahlekelwa ezimweni ezivame kakhulu.
Ukucushwa Okuyinhloko Okuncane Kwezitho Ezintathu:
Umklamo olinganayo ulinganisela i-magnetic flux, unciphisa ukulahlekelwa yi-zero-sequence futhi uthuthukise ukufana kokushisa.
2. Izinhlelo Zokuvikela
Ukufakwa Kokumbozwa Kwephepha Elihlanganisiwe Lamafutha:
Iphepha le-cellulose elisezingeni eliphezulu elifakwe uwoyela wokuvikela (isb., uwoyela we-naphthenic noma we-paraffinic mineral) linikeza amandla e-dielectric afinyelela ku-300 kV BIL.
Ihlanganisa ukuzinza kokushisa (imelana namazinga okushisa afinyelela ku-140°C) kanye nokumelana nomlilo.
I-Epoxy Resin Coating (I-Dry-Type Hybrid):
I-epoxy resin engakhiphi kahle evikela ukukhishwa kwekhoyili, ethuthukisa ukumelana nomswakama kanye nokungcola.
Ukufakwa Kokushisa Okuthuthukisiwe Kwe-Nano:
Izinhlanganisela ze-epoxy ezigcwele i-silica zithuthukisa isikhathi sokukhishwa kwengxenye ngo-30-50%, okulungele izindawo ezisogwini noma zezimboni.
3. Ukuphathwa Kokushisa
Ukupholisa Umoya Okwenziwa Ngowoyela-Okwemvelo (i-ONAN):
Ukupholisa okungenamsebenzi ngama-radiator kanye ne-convection yamafutha yemvelo, efanelekile ukusebenza okuqhubekayo emithwalweni elinganisiwe.
Ukupholisa Umoya Ophoqelelwe (OFAF):
Amafeni alawulwa amazinga okushisa athuthukisa ukushabalaliswa kokushisa, okwenza kube nomthamo wokulayisha ngokweqile ongu-120% isikhathi esifushane.
Ukupholisa Okusizwa Yiphampu Kawoyela (OFWF):
Amaphampu okujikeleza uwoyela kanye namafeni omoya ophoqelelwe athuthukisa ukudluliselwa kokushisa kweziteshi ezincane zasemadolobheni ezinabantu abaningi.
Ukuqapha Okuhlakaniphile Kokushisa:
Izinzwa zokushisa ezifakiwe kanye nezinhlelo ezisebenzisa i-IoT ziqala ama-alamu, ukucima komthwalo, noma ukusebenza kokupholisa ukuvimbela ukonakala kokushisa.
4. Umklamo Nokuvikelwa Kwesakhiwo
Ithangi Eliqinile kanye Nokumbozwa
Amathangi Angamelani Nokugqwala:
Izivalo zensimbi ezifakwe ngogesi noma ze-aluminium ezifakwe ngogesi ezishisayo ezine-polyurethane/impuphu zimelana nokuwohloka kwe-UV, ukufuthwa ngosawoti, kanye nokuchayeka kumakhemikhali.
Ukuvalwa Okungangenisi Umswakama:
Amathangi ashiselwe noma aboshwe ngama-gasket e-EPDM avimbela ukuvuza kukawoyela nokungena komswakama, okuqinisekisa ukusebenza okungenakulungiswa amashumi eminyaka.
Ukwelashwa Kokulwa Nokugqwala:
Izinhlelo zokuvikela i-Cathodic kanye nezingubo ezingagqwali zandisa isikhathi sokuphila ezindaweni ezine-acidic noma ezinomswakama.
Izici Zokuphepha
Ama-Valve Okunciphisa Ukucindezeleka:
Ukukhipha amagesi ngokuzenzakalelayo ngesikhathi sokuphuka kwangaphakathi (isb., ama-short circuits), ukuvimbela ukuqhekeka kwethangi.
Uhlelo Lokulondolozwa Kwamafutha:
Amathangi okugcina noma ama-conservator avalwe ngendwangu anciphisa ukuthintana komoya-mpilo, anciphise ukushiswa komoya-mpilo kanye nokwakheka kodaka.
Ukuvikelwa Kokukhuphuka:
Ama-integrated zinc oxide arresters (MOA) kanye nama-surge capacitors acindezela ama-transients abangelwa umbani.
5. Imisebenzi Ethuthukisiwe
Izinhlelo Zokuqapha Isimo (i-CMS):
Izinzwa zilandelela izinga lokushisa likawoyela, ukuhlaziywa kwegesi encibilikisiwe (i-DGA), amazinga omthwalo, kanye nokukhishwa kwengxenye, okuvumela ukulungiswa okubikezelayo nge-SCADA.
Abashintshi Bempompi Abalayishwayo (OLTC):
Ukulungiswa kwempompi okuqhutshwa yi-AI kuthuthukisa ukulawulwa kwamandla kagesi ngaphansi kwemithwalo yegridi eguquguqukayo, kunciphisa ukulahleka kwamandla ngamaphesenti afinyelela ku-5.
Izinto Ezintsha Ezingachemi Imvelo:
Amafutha okuvikela asekelwe ku-bio (isb., uketshezi lwe-ester) anokubola okuphezulu kanye nokusha okuncane, okuhambisana nezindinganiso ze-IEC 62721.
Izicelo Eziyinhloko kanye Nezindlela Zesikhathi Esizayo
Ukusatshalaliswa Kwezimboni Nasemadolobheni:
Amafektri kagesi anamayunithi aphezulu (500kVA–5MVA), izakhiwo zezentengiselwano, kanye namadolobha ahlakaniphile.
Ukuhlanganiswa Kwamandla Avuselelekayo:
Ilungele iziteshi ezincane zepulazi lomoya/ilanga kanye nama-microgrid, isekela ukugeleza kwamandla okuya ohlangothini olubili.
Intuthuko Yesikhathi Esizayo:
Ama-Transformers Esifundazwe Esiqinile (ama-SST): Nika amandla ukuguqulwa kwe-DC-DC kanye nokuguquguquka kwegridi kwezinhlelo zamandla ezihlukaniswe ngokwezigaba.
Ukuzivikela Okuziphilisayo: Izinto ze-nanocomposite zilungisa ngokuzimela amaphutha amancane e-dielectric.
Isifinyezo
Ama-Transformer Okusabalalisa Afakwe Kuwoyela Anezigaba Ezintathu asebenza kahle ngokusebenzisa ama-core angenawo ukwakheka aphansi, ukuphathwa kokushisa okuthuthukisiwe, kanye nezinhlelo zokuphepha ezinezingqimba eziningi. Inhlanganisela yawo yokusebenza kahle, ukuguquguquka, kanye nokuqina iwenza abe yinto ebalulekile kumagridi kagesi esimanje, kuyilapho izinto ezintsha ezifana namafutha asekelwe ku-bio kanye nobuhlakani



Buza Manje!
Uma unemibuzo mayelana nemikhiqizo yethu noma uhlu lwamanani, sicela usishiyele i-imeyili yakho futhi sizoxhumana nathi zingakapheli amahora angama-24.