Leave Your Message

Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA

I-power transformer iyisici esibalulekile ezinhlelweni zikagesi, eyenzelwe ukudlulisa ngempumelelo ugesi oshintshashintshayo (AC) phakathi kwamasekethe emazingeni e-voltage ahlukahlukene. Ilungele ukwenyusa noma ukwehlisa ama-voltage, lawa ma-transformer aqinisekisa ukusatshalaliswa kwamandla okuthembekile kumagridi wamandla, izikhungo zezimboni, kanye nezinhlelo zokusebenza zezentengiselwano. Njengoba aklanyelwe ukuqina nokusebenza kahle, ama-power transformer ethu ahlangabezana nezindinganiso zomhlaba wonke (IEC, IEEE) ngenkathi ebeka phambili ukuphepha, ukusebenza kahle, kanye nokusimama.

    Amapharamitha omkhiqizo

    Uhlobo​

    Umthamo

    Izinga Le-Voltage

    Ukupholisa

    Isicelo

    Isiguquli Sokusabalalisa

    1,600 kVA

    11 kV / 400 V

    INTSHA

    Izindawo zokuhlala/zezimboni

    Isiguquli Samandla

    500 MVA

    220 kV / 33 kV

    I-OFAF

    Isikhungo sokudlulisa izimpahla esifundeni

    Isiguquli se-UHVDC

    ±400 kV / 500 MVA

    I-HVDC engu-±800 kV

    Uwoyela ophoqelelwe

    Amagridi aphakathi kwezwekazi

    Isiguquli Sokulungisa Izinto

    Ama-MVA angu-20

    33 kV / 1.8 kV × 6-pulse

    Uhlobo olomile, olupholile emoyeni

    I-electrolysis ye-aluminium

    I-Transformer Ecwiliswe Kuwoyela we-Cooper Imvamisa Ephakeme 10001I-Transformer Ecwiliswe Kuwoyela we-Cooper Imvamisa Ephakeme 10002I-Transformer Ecwiliswe Kuwoyela we-Cooper Imvamisa Ephakeme 10003
    Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA (1)Izixazululo Zezinguquko Zamandla Enziwe Ngokwezifiso≤2500 kVA (2)Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA (3)Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA (4)Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA (5)
    • Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA (1)
    • Izixazululo Zezinguquko Zamandla Enziwe Ngokwezifiso≤2500 kVA (2)
    • Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA (3)
    • Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA (4)
    • Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA (5)
    • Izixazululo Zokuguqula Amandla Ngokwezifiso≤2500 kVA (6)
    I-Transformer Ecwiliswe Kuwoyela we-Cooper01

    incazelo yomkhiqizo

    1. Amandla Alinganisiwe (i-MVA/kVA)​​
    Incazelo: Ukukhishwa kwamandla okuqhubekayo okuphezulu kakhulu i-transformer engakunikeza.
    Ububanzi Obujwayelekile:
    Ama-Transformer Okusabalalisa: ≤2,500 kVA (isb., ukusatshalaliswa kwezindawo zokuhlala noma zezimboni).
    Ama-Power Transformers: Izinkulungwane ze-kVA kuya kuma-GVA amaningana (isb., iziteshi zokudlulisa).
    Ama-Transformer e-Ultra-High Voltage (UHV): Okuxhumana kwegridi noma ukusetshenziswa kwezimboni, ama-transformer e-HVDC afinyelela ku-±800 kV.
    2. Isilinganiso se-Voltage​
    Ama-Voltage Okufaka/Okukhipha:
    I-High Voltage (HV): Ngokuvamile ​33 kV kuya ku-±1,100 kV​ (isb., amanethiwekhi okudlulisa).
    I-Voltage Ephakathi (MV): Ejwayelekile ​11 kV, 22 kV, 33 kV.
    I-Voltage Ephansi (LV): Ngokuvamile i-400 V noma i-6.6 kV (ukusatshalaliswa kubasebenzisi bokugcina).

    Izicelo Ezikhethekile:
    Ama-Rectifier Transformers: Kwamakhemikhali/izinsimbi, ama-voltage afinyelela ku-​30 kV+​.
    Ama-Transformer Okudonsa Isitimela: Alungiselwe amandla esitimela, isib., 27.5 kV noma 1×25 kV.
    3. Imvamisa​
    Okujwayelekile: 50 Hz (eShayina/eYurophu) noma 60 Hz (eNyakatho Melika).
    Amaza Akhethekile: 400 Hz wezinhlelo zokusebenza zezindiza/zasolwandle.
    4. Uhlelo Lokupholisa​
    Okucwiliswe ku-oyela:
    ​ONAN​ (Amafutha Omoya Wemvelo): Ukupholisa kwe-convection yemvelo.
    ​ONAF​ (Amafutha Aphoqelekile Umoya Wemvelo): Ukupholisa umoya okuphoqelekile ukuze kusebenze kahle kakhulu.
    Uhlobo Lokomile: Kupholiswe ngomoya, kufanelekela izindawo ezingaphakathi/ezizwela umlilo (isb., izikhungo zedatha).
    ​I-Gas-Insulated (GIS): I-SF6 gas insulation, idizayini encane yeziteshi ezincane ezinabantu abaningi.
    5. Uhlobo Lokuvala Ukushisa​
    ​Ocwiliswe Kuwoyela: Uwoyela wamaminerali noma uwoyela osekelwe ku-ester (ongangcolisi imvelo).
    Uhlobo Lokomile: Ukuphonswa kwe-resin ye-Epoxy noma i-Nomex paper insulation (ingamelani nomlilo/ukuqhuma).
    Igesi Efakwe Ukushisa: I-SF6 noma amagesi axubile (iziteshi ezincane eziqinile ezine-voltage ephezulu).
    6. Ukusebenza kahle​
    Amanani Ajwayelekile:
    Ama-Transformer Okusabalalisa: ≥98% (ukulahlekelwa okuphansi komthwalo kanye nokulahlekelwa komthwalo).
    Ama-Power Transformers: ≥99% (amamodeli e-voltage aphezulu kakhulu afinyelela ukusebenza kahle okukhulu nakakhulu).
    Izindinganiso: Zithobela i-IEC 61620 noma i-IEEE C57.12 (isib., izidingo ze-EU Ecodesign).
    7. Iqembu Lokuxhumana​
    Umehluko Wesigaba: Kuhlonzwe njengo-Dyn11, Yd11, okubonisa ubudlelwano besigaba phakathi kwama-windings ukuphatha ama-harmonics kanye nemisinga ye-short-circuit.
    8. I-Impedance Voltage​
    Incazelo: Ukwehla kwephesenti lamandla kagesi ngesikhathi sokuhlolwa kwe-short-circuit, okubonisa ikhono lokumelana ne-short-circuit.
    Amanani Ajwayelekile: 4–10% (ama-transformer kagesi), ≤4% (ama-transformer okusabalalisa).
    9. Ukunyuka Kwezinga Lokushisa​
    Imikhawulo: Ama-transformer acwiliswe uwoyela ngokuvamile avumela ukwenyuka kwezinga lokushisa elingu-≤55 K (uwoyela ophezulu endaweni engama-40°C).
    Ukuzivumelanisa Nemvelo: Izindawo zasehlane zidinga ukuhlanzeka okukhulu.
    10. Isilinganiso Sokuvikelwa​
    Amakhodi e-IP:
    I-IP23: Isifutho esivikelwe uthuli, esingangeni manzi.
    I-IP66/IP68: Ivalwe ngokuphelele uthuli/amanzi (izinhlelo zokusebenza zasolwandle/zasogwini).
    Izindawo Ezikhethekile: Ukumelana nokugqwala kwesifutho sikasawoti ukuze kusetshenziswe ogwini/ngaphansi kolwandle.
    ​11. Izinhlobo Ezikhethekile​
    Ama-Rectifier Transformers: Amadizayini e-Multi-pulse (isb., 12/24-pulse) ukuze kuncishiswe ama-harmonics.
    Ama-Transformer Ashintsha Ukuthepha: Ama-tap changer afakwa ku-load (OLTC) okulawula i-voltage.
    Ama-Transformer Akhethekile:
    Ama-Transformer e-Furnace kagesi: Aklanyelwe ukugcwala ngokweqile kwesikhathi esifushane (isb., ukuncibilikisa insimbi).
    Ama-Zigzag Transformers: Izinhlelo zokumisa ezingathathi hlangothi zokucindezela i-harmonic.

    Uhlobo​ Isicelo Sokupholisa Izinga Le-Voltage Lomthamo

    Isiguquli Sokusabalalisa 1,600 kVA 11 kV / 400 V ONAN Izindawo zokuhlala/zezimboni
    I-Power Transformer engu-500 MVA 220 kV / 33 kV OFAF Isikhungo sokudlulisa igesi sesifunda
    I-UHVDC Converter Transformer ±400 kV / 500 MVA ±800 kV I-HVDC Amafutha aphoqelelwe Amagridi aphakathi kwamazwekazi
    I-Rectifier Transformer engu-20 MVA 33 kV / 1.8 kV × 6-pulse I-electrolysis ye-aluminium yohlobo olomile, epholiswe ngomoya
    I-Transformer Ecwiliswe Kuwoyela we-Cooper02I-Transformer Ecwiliswe Kuwoyela we-Cooper03I-Transformer Ecwiliswe Kuwoyela we-Cooper04I-Transformer Ecwiliswe Kuwoyela we-Cooper05

    Kungani ukhethe thina

    I-JIEZOU POWER, umklami ochwepheshe, umenzi kanye nomfaki wesisombululo sesistimu yamandla emhlabeni jikelele, yasungulwa ngonyaka we-1989, ithatha indawo engamamitha-skwele angama-200,000.
    I-JIEZOU POWER, iphatha kakhulu amaphrojekthi egridi kagesi, i-500KV EPC, isitshalo sikagesi samanzi esingu-230KV, isiteshi sikagesi esingu-115KV, njll.
    Ifektri ye-JIEZOU POWER ingakhiqiza i-transformer yokusabalalisa uhlobo lwamafutha kanye nohlobo olomile, i-transformer yamandla engu-500KV 480MVA ephezulu, i-GIS, i-switchgear, isiteshi esincane, ngokusekelwe ku-ANSI/IEEE/DOE2016/CSA/IEC60076 ejwayelekile.
    I-JIEZOU POWER ithola isitifiketi se-ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. Kuze kube ngunyaka ka-2023, izinkampani zamagatsha kanye nezimboni emhlabeni wonke zisatshalaliswa e-United States, eCanada, eDubai, eDominican Republic, ePhilippines, izimboni kanye nezinkampani zamagatsha aseShayina zisedolobheni laseBengBu, edolobheni laseFengYang, edolobheni laseHaiAn, edolobheni laseTaiZhou, edolobheni laseSuZhou, edolobheni laseShenYang, edolobheni laseFoShan.
    Uma sibheka ikusasa, umbono we-JIEZOU POWER uwukuba ngumhlinzeki wezixazululo zesistimu yamandla othembekile kakhulu, ukuxazulula izinselele zokuphathwa kwamandla eziphuthumayo kakhulu emhlabeni, ukusheshisa ukushintshela kweplanethi kumandla avuselelekayo. Ukuze wonke umuntu abe nokuphila okunekhabhoni ephansi futhi okukhanyayo. Ngenxa yalokhu, sizokwenza konke okusemandleni ethu ukwenza imizamo.
    I-Transformer Ecwiliswe Kuwoyela we-Cooper06I-Transformer Ecwiliswe Kuwoyela we-Cooper07I-Transformer Ecwiliswe Kuwoyela we-Cooper08I-Transformer Ecwiliswe Kuwoyela we-Cooper09

    Buza Manje!

    Uma unemibuzo mayelana nemikhiqizo yethu noma uhlu lwamanani, sicela usishiyele i-imeyili yakho futhi sizoxhumana nathi zingakapheli amahora angama-24.

    Leave Your Message