+86 18068001229 Iyini i-Transformer efakwe ePad? Umhlahlandlela Ophelele
I-Transformer Efakwe EmaphethiniAma-PMT (ama-PMT) angamaqhawe angadunyiswanga okusatshalaliswa kukagesi kwesimanje. Njengezingxenye ezibalulekile zamanethiwekhi kagesi asemadolobheni nasemaphandleni, lawa mayunithi amancane, asezingeni eliphansi aletha ugesi ngokuphephile emakhaya, emabhizinisini, kanye nengqalasizinda yomphakathi. Kodwa yini ngempela eyenza abaluleke kakhulu?
Ukuchaza Ama-Transformer Afakwe Ku-Pad
I-transformer efakwe kuma-pad iyi-enclosed, efakwe phansi Isiguquli Sokusabalalisa Ugesi Ifakwe ephepheni likakhonkolo. Yakhelwe ukusetshenziswa ngaphandle, yehlisa ugesi onamandla aphezulu (ngokuvamile u-15kV-35kV) ibe amazinga angasetshenziswa amandla aphansi (120V-600V) kubathengi bokugcina.
Izingxenye Eziyinhloko:
Ithangi kanye Nokumbozwa
Indlu yensimbi engangenisi manzi enezikhiye ezingaphazamisi
Izembozo ezingamelani nokugqwala iminyaka engaphezu kwengu-30 yokuphila
I-Core & Windings
Ama-core ensimbi ye-silicone anezimbobo zethusi/i-aluminium
Uhlelo Lokupholisa
Imiklamo epholile nge-convection (OA) noma ephoqelekile emoyeni (FA)
Ama-Bushing
Idizayini eqondile yokuphepha okuthuthukisiwe
Izinhlelo Zokuvikela
Amadivayisi okusiza ukucindezeleka, izinkomba zamaphutha, izinto zokuvimba ukukhuphuka kwengcindezi
Kungani Kufanele Ukhethe Ama-Transformer Afakwe Ku-Pad? Izinzuzo Ezi-5 Ezibalulekile
① Umklamo Wokonga Isikhala
Ngokuxhumeka kwekhebula elingaphansi komhlaba kanye nezinyathelo ezincane (ngokuvamile eziyi-1.5mx 2m), ama-PMT aqeda isidingo semigqa engenhla kanye nezinsika - alungele izindawo ezixineneyo zasemadolobheni kanye nezindawo ezizwela ubuhle.
② Ukuphepha Komphakathi Okuthuthukisiwe
Izindonga ezivaliwe zivimbela ukufinyelela okungagunyaziwe
Izinhlelo zokulawula uwoyela ezicwiliswe emanzini zihlangabezana nezimfuneko ze-EPA
Ukuvikelwa kwamanje okungenaphutha kunciphisa izingozi zomlilo
③ Izindleko Zokulungisa Ezincishisiwe
Njengoba inamathangi avaliwe kahle kanye nokufakwa kokushisa okumelana nomswakama, ama-PMT esimanje adinga ukulungiswa okungaphansi ngo-50% kunezinyunithi ze-pole-top ezisekelwe ezindinganisweni ze-IEEE C57.12.00.
④ Ukuthembeka kwegridi
Ama-transformer afakwe kuma-pad avumela ukucushwa kwe-loop feed - uma iyunithi eyodwa yehluleka, ukushintsha kwenethiwekhi ngokuzenzakalela kushintsha umzila wamandla ukuze kuncishiswe ukungasebenzi.
⑤ Ukuguquguquka Kwendlela Ozenza Ngayo
Itholakala ngezilungiselelo zesigaba esisodwa (25-500kVA) kanye nezigaba ezintathu (75-5,000kVA) kanye nezinketho zalokhu:
Ukunciphisa i-Harmonic
Imiklamo yomsindo ophansi (
Amamodeli asebenza kahle kakhulu (ahlangabezana nezindinganiso ze-DOE 2023)
Izicelo: Lapho i-Pad Mounters Power Imiphakathi
Ukwakhiwa kwezindlu kanye nokwahlukaniswa kwezindawo
Izitolo ezinkulu kanye nezindawo zokuhweba
Amakhampasi ezibhedlela kanye namayunivesithi
Amapaki ezimboni (anezivikelo ze-arc flash)
Ukuxhumana kwamandla avuselelekayo