+86 18068001229 Iyini i-Mining Lighting Transformer?
AIsiguquli Sokukhanyisa Kwezimayiniuhlobo olukhethekile lwe-transformer oluklanyelwe ngqo ukunika amandla izinhlelo zokukhanyisa ezimayini (kufaka phakathi izimayini zamalahle nezingezona zamalahle). Umsebenzi walo oyinhloko ukuhlinzekakuphephile, kuthembekile, futhi kuzinzilei-voltage ephansi yokusebenzisa imishini yokukhanyisa engaphansi komhlaba.
Izici Eziyinhloko kanye Nenhloso Yokuklama:
Ukuguqulwa kwe-Voltage:Ngokuvamile iguqula i-voltage ephezulu yegridi yamandla yemayini (isb., 660V, 1140V) ibe yi-I-Safety Extra-Low Voltage (SELV)okudingekayo ohlelweni lokukhanyisa, ngokuvamile127VLeli zinga le-voltage libhekwa njengeliphephile kakhulu ezindaweni ezimanzi nezihambisa ugesi, okunciphisa kakhulu ingozi yokushaqeka kukagesi.
Ukuhlukaniswa Kokuphepha:Kuyi-Isiguquli Sokuzihlukanisa. Ukugoqa kwayo kwesibili (uhlangothi lokukhipha) kuhlukaniswe ngogesi emhlabeni kanye nokugoqa okuyinhloko (uhlangothi lokufaka). Lokhu kusho ukuthi noma ngabe umvukuzi uthinta umugqa owodwa wokukhipha kwe-127V kanye nomhlabathi ngasikhathi sinye, isekethe evaliwe ngeke yakheke, ngaleyo ndlela kuvinjelwe ukushaqeka kukagesi.
Umthwalo Ozinikele:Inhloso yomklamo wayo ngokuyinhloko ukuhlinzeka ngemithwalo yokukhanyisa (isb., izibani ze-incandescent, izibani ze-LED). Izici zomthwalo zizinzile, futhi umthamo uvame ukuba mncane (kusukela ku-kVA embalwa kuya kumashumi amaningana e-kVA).
Isivikelo Esiyisisekelo:Nakuba futhi inezici ezithile zokuvikela izimayini (njengokumelana nomswakama, ukumelana nokushaqeka), ukugxila kwayo okuyinhloko ukuhlinzeka ngomthombo wamandla ophephile, hhayi ukusingatha amazinga aphezulu amagesi aqhumayo.
Kalula nje, i-Mining Lighting Transformer "inhliziyo ephephile" yesekethe yokukhanyisa yemayini; umsebenzi wayo oyinhloko "ukuvimbela ukushaqeka."
Iyini i-Transformer Yezimayini Engaqhumi?
I-AnIsiguquli Sezimayini Esingavimbeli UkuqhumaUmqondo obanzi obhekisela kuzo zonke iziguquli zezimayini ezenzelwe ukuvimbela ukushiswa kwezingxube zegesi eziqhumayo ezizungezile futhi zingasetshenziswa ezindaweni eziyingozi eziqhumayo. Akuyona nje umthombo wamandla wezinhlelo zokukhanyisa kodwa kuyingxenye eyinhloko yesistimu yonke yamandla angaphansi komhlaba.
Izici Eziyinhloko kanye Nenhloso Yokuklama:
Ukwakhiwa Okungenakho Ukuqhuma:Lesi yisici sayo esiyinhloko. Isebenzisa izindawo ezikhethekile ezingangeni ukuqhuma ("Izinhlobo Zokuvikela"), isibonelo:
Indawo Engangenisi Umlilo ('Ex d'):Indawo ebiyelwe ingamelana nokuqhuma kwangaphakathi futhi ivimbele ilangabi langaphakathi ukuthi lingasabalali liye emoyeni wangaphandle, ngaleyo ndlela lingavuthisi igesi ezungezile.
Ukuphepha Okuthuthukisiwe ('Ex e'):Kusetshenziswa izinyathelo ezengeziwe ku-transformer kanye nama-terminals angakhiqizi ama-arcs, ama-spark, noma izindawo ezishisayo eziyingozi ngesikhathi sokusebenza okuvamile, okuthuthukisa ukuphepha.
Amandla Aphezulu:Umthamo uvame ukuba mkhulu (kusukela emashumini e-kVA kuya ezinkulungwaneni eziningana ze-kVA), osetshenziselwa ukunika amandla imishini ehlukahlukene enamandla amakhulu ngaphansi komhlaba, njengeabachebi bezinwele, ama-roadheader, amabhande okuhambisa, amaphampu amanzi, kanye namafeni asekelayo.
Ama-Voltage Okukhipha Ahlukahlukene:I-voltage yayo yokukhipha iyahlukahluka kuye ngezidingo zemishini exhunyiwe, okungaba amazinga e-voltage aphakathi njengo-660V, 1140V, 3300V, njll. Ingase futhi ifake i-winding engu-127V yokukhanyisa, kodwa lokhu akuwona umsebenzi wayo oyinhloko.
Ukuvikelwa Okuphelele:Ngaphandle kokuthi ingaqhumi, kumele futhi ibe nesakhiwo esiqinile semishini, ukumelana nomswakama okuhle kakhulu, ukumelana nokugqwala, kanye nokumelana nokushaqeka ukuze ivumelane nesimo esinzima sokusebenza ngaphansi komhlaba.
Kalula nje, i-Transformer Yezimayini Engaqhumi "iyinsika yamandla engaqhumi" yesistimu yamandla eshukumisayo yemayini; umsebenzi wayo oyinhloko "ukuvimbela ukuqhuma" nokuhlinzeka ngamandla emishini ehlukahlukene.
Umehluko Obalulekile Phakathi Kwababili
Ukuze uthole ukuqhathanisa okunembile, sicela ubheke ithebula elingezansi: