Leave Your Message
Izigaba Zezindaba
Izindaba Ezivelele

Ziyini Iziguquli Ze-Amorphous Alloy? Izinzuzo Eziyinhloko Zokukhetha Iziguquli Ze-Amorphous Core

2025-11-03

Isiguquli se-Amorphous Alloys, ngokulahlekelwa kwazo okuphansi kakhulu kanye nokusebenza kahle kwamandla okuphezulu, ziye zavela njengezindlela ezintsha zokushintsha ama-transformer ensimbi ye-silicon yendabuko. Lesi sihloko sihlola izimiso zawo zobuchwepheshe, izinzuzo, izinhlelo zokusebenza, kanye nokwamukelwa okuqhutshwa yinqubomgomo ukuze kuqondiswe ukwenza izinqumo ezinolwazi.

 

 

Mina.Ama-Transformers e-Amorphous Alloy: Incazelo kanye nobuchwepheshe

1Ukusungula Izinto Ezintsha

Ukusetshenziswa kwe-u coreamaribhoni ensimbi angenasimo sensimbi(ubukhulu obungu-0.02-0.04mm) bakhiwe ngokupholisa okusheshayo kakhulu. Isakhiwo sabo se-athomu esingahlelekile (esifana nengilazi) siqeda ukulahlekelwa kwemingcele yokusanhlamvu, sithuthukise ukusebenza kahle kokubutha ngo-40-60% ngaphezu kwensimbi ye-silicon.

2Umklamo Wesakhiwo

kuUmongo:Umklamo wezinyawo ezinhlanu wesigaba sesithathu unciphisa ama-harmonics esithathu futhi uthuthukisa ukumelana kwe-short-circuit ngo-30%.

kuAma-winding:Ukukhishwa kwe-vacuum cleaner ye-Epoxy resin (ukushisa kwe-Class H, isilinganiso esingu-180°C), ukumelana nomswakama, ukufuthwa ngosawoti, kanye nesikhunta.

kuUkupholisa:Ithangi elihlanganisiwe elivaliwe eline-natural (AN) noma i-forced air cooling (AF), elisekela umthamo wokulayisha ngokweqile ongu-150%.

 

 

II.Izinzuzo Ezi-5 Eziyinhloko Zama-Amorphous Alloy Transformers

1.Ukulahlekelwa Okuphansi Kakhulu, Ukonga Okuqinisekisiwe

lUkulahlekelwa okungadingi mthwalo okuphansi ngo-70-80%:Ukumelana kwe-amorphous alloy kuphakeme ngokuphindwe ka-3-6 kunensimbi ye-silicon. Isibonelo: 10kV/400kVA i-amorphous transformer ukulahlekelwa okungenamthwalo = 215W uma kuqhathaniswa no-570W wensimbi ye-silicon.

lI-TCO ephansi:Naphezu kwezindleko zangaphambilini eziphakeme ngo-30%, ukonga amandla ngonyaka okungu-$7,000+ kuletha imbuyiselo yeminyaka engu-3-5.

2.Ukuhambisana Okungachemi Imvelo, Okungathathi Ikhabhoni

lUkwehliswa kwe-CO₂:Amathani angu-5-8 ngonyaka ngeyunithi ngayinye; SO₂ yehliswe ngamathani angu-0.1.

lUmjikelezo wokuphila ozinzile:Uwoyela ongu-1L ogciniwe ngekhilogremu ngayinye yengxube ekhiqizwayo; ama-core angasetshenziswa kabusha angu-100%.

3.Ukuthembeka Okuphezulu Ezimweni Ezinzima

lUkubekezelelana kwe-Harmonic:Amamodeli e-SCRBH15 asebenza ngokuqina ngaphansi kwe-THD ≤5% (afanele ama-inverter e-PV/ama-VFD).

lUkuvikelwa okuqinile:Isilinganiso se-IP23 se--40°C kuya ku-+45°C, umswakama ongu-100%.

4.Isikhathi Sokuphila Seminyaka Engu-30 Nokunganakekelwa

lUkuguga kancane kokushisa:1/3 izinga lokuwohloka kwensimbi ye-silicon.

lIdizayini engenawo amafutha:Kuqeda ukuvuza; Ukuqapha izinga lokushisa le-IoT.

5.Izikhuthazo Zenqubomgomo

lUkuqeda okuphoqelekile:IShayina izoyeka ukusebenza ama-transformer e-S7 ngo-2025; isabelo semakethe esingu-≥80% samamodeli asebenza kahle kakhulu.

lIzibonelelo:Izaphulelo ezingu-10% zamamodeli okusebenza kahle kweKlasi 1 ezifundazweni eziningi.

 

 

III.Izinhlelo Zokusebenza Eziyinhloko kanye Nenani Lomsebenzisi

1.Amandla Avuselelekayo

lIsinyathelo sokwenyuka kwelanga/komoya:Ipulazi le-2GW likaNingxia lisindisa i-¥1.2M ngonyaka nge

l kunciphisa ukulahleka komthwalo ebusuku.

lIsitoreji samandla:Imelana nemijikelezo yokushaja/yokukhipha igesi njalo.

2.AmaGridi aseMadolobheni

lIzindawo zokuhweba:I-Shanghai mall ithole inzuzo yokusebenza kahle engu-18% ngama-transformer e-SCBH15.

lIzinhlelo zeMetro:Umugqa we-Guangzhou 18 usebenzisa izinhlobo ezomile ezingashisi umlilo ukuze kuphephe ngaphansi komhlaba.

3.Ukusetshenziswa Kwezimboni

lImishini yokugaya insimbi:Isekela ukujikijelwa komthwalo wesithando somlilo se-arc, isindisa ama-¥500,000 ngonyaka.

lIzindawo zokucwenga uwoyela:Amamodeli angaqhumi aqinisekisa ukusebenza okungenamaphutha iminyaka engaphezu kwemi-5 eXinjiang.

 

 

IV.Izinkombandlela Zokuthambekela Nokukhetha

1.Imephu Yobuchwepheshe

lUkuqapha okuhlakaniphile:Izinhlelo ze-DGA eziku-inthanethi (ukunemba kokubikezela amaphutha okungu-≥95%).

Ukuthuthukiswa kwezinto ezibonakalayo:Ama-core e-nanocrystalline azonciphisa ukulahlekelwa ngo-30% (okwentengiso ngo-2025).

2.Imithetho Yokukhetha

(1)Amaphrofayili okulayisha afanayo:Beka phambili ukungabi nasimo ezimweni zomthwalo ophansi (ukushaja kwe-EV); insimbi ye-silicon yomthwalo ophakeme (izikhungo zedatha).

(2)Bala i-TCO:I-Amorphous inikeza izindleko zeminyaka engu-20 eziphansi ngo-25-30% (ukuthenga + amandla + ukulungiswa).

(3)Qinisekisa izitifiketi:Funa imibiko yokuhlolwa kwe-CTI/STL yokwenyuka kwezinga lokushisa kanye nokuhlolwa kwe-short-circuit.

 

 

Isiphetho
Ama-transformer e-alloy amorphous ahola phambili emakethe ngeukonga amandla,ukusimama,kanye nokuthembeka, okuthuthukisa ukwenziwa kwesimanje kwegridi kanye nokuthuthukiswa kwezimboni. Isabelo sabo semakethe yomhlaba wonke kulindeleke ukuthi sikhule sisuka ku-26.8% (2023) siye ku-35% ngo-2026. Hlanganisa ukukhetha namaphethini omthwalo kanye nezibonelelo ukuze wandise i-ROI.