+86 18068001229 Ukuqhathanisa Kobuchwepheshe: I-Isolation Transformer vs. I-Okuvamile Transformer
- Izinhloso Eziyinhloko Zokusebenza
Ama-Transformer Ajwayelekile
Yenzelwe ngokuyinhloko ukuguqulwa kwe-voltage (isinyathelo-phezulu/phansi), ngesilinganiso sokujika esingalingani phakathi kwama-windings ayisisekelo/awesibili. Inhloso yabo eyisisekelo ukuguqulwa kwe-voltage ye-AC ukuze kuhlangatshezwane nezidingo zomthwalo.
Gxila ekuhlukanisweni kwe-galvanic kunokuguqulwa kwe-voltage. Nakuba amanye amamodeli egcina isilinganiso sokujika esingu-1:1, indima yawo ebalulekile ukuphula izindlela zikagesi eziqondile phakathi komthombo nomthwalo ukuqinisekisa ukuphepha.
- Ifilosofi Yokuklama
Ama-Transformer Ajwayelekile
Yakhiwe nge-magnetic coupling evumela ukuguqulwa kwe-voltage. Ama-Autotransformers (i-subtype) abelana ngama-windings okuklama okuhlangene kodwa awanawo amakhono okuzihlukanisa.
Ama-Transformer Okuzihlukanisa
Ifaka ukuhlukaniswa okuphindwe kabili okunezivikelo ze-electromagnetic. Amamodeli athuthukile afaka amakheji e-Faraday ukucindezela umsindo wemodi evamile kanye nama-transients.
- Imininingwane Yokuphepha
| Ipharamitha | I-Transformer Ejwayelekile | Isiguquli Sokuzihlukanisa |
| Amandla e-Dielectric | 1,000V (okuvamile) | ≥1,500V (ihambisana ne-IEC 61558-1) |
| Ukuvuza Kwamanje | Kufika ku-3.5mA |
|
| Ukucushwa Kokumisa Isisekelo | Isisekelo esingathathi hlangothi | Indawo entantayo noma indawo ekhethiwe yokumisa |
- Izimo Zokusebenza
Ama-Transformer Ajwayelekile
Izinhlelo zokulawula ezenzakalelayo zezimboni
Inhloso evamile Ukusatshalaliswa Kwamandla (isb., ukuguqulwa okungu-380V→220V)
Izinhlelo zokusebenza ezithinta izindleko ngaphandle kwezidingo zokuphepha eziqinile
Ama-Transformer Okuzihlukanisa
Imishini yokuthwebula izithombe zezokwelapha (izikena ze-MRI/CT)
Izinhlelo zezinsimbi zelebhu kanye nezomsindo/ividiyo
Izixhumi zamandla avuselelekayo (ama-inverter elanga)
- Ukusetshenziswa Kobuchwepheshe
Imikhuba Yokuxhuma Izintambo
Okuvamile: Ukuxhumana okuqondile okungenasigaba
Ukuhlukaniswa: Imigqa ye-PE/N enikezelwe ngokuqapha ukuvikela
Ukusebenza kwe-EMI
Okuvamile: Kuthinteka umsindo oqhutshwayo (ama-harmonics angu-50/60Hz)
Ukuhlukaniswa: >60dB isilinganiso sokwenqatshwa kwemodi evamile (CMRR)
- Izindinganiso Zokuthobela
Okuvamile: IEC 60726-2 (izicelo zezimboni)
Ukuhlukaniswa: IEC 61558-1/2 (izinhlelo ezibaluleke kakhulu ekuphepheni), UL 1950 (amadivayisi ezokwelapha)
Lokhu kuqhathanisa okuhlelekile kugqamisa indlela ama-transformer okuzihlukanisa ahlinzeka ngayo ngezinzuzo ezibalulekile zokuphepha ngokusebenzisa ubuchwepheshe obuthuthukisiwe bokufudumeza nokucindezela umsindo, kuyilapho ama-transformer avamile ebeka phambili ukuguqulwa kwe-voltage okungabizi kakhulu. Ukukhetha kuncike ezidingweni ezithile zokuphepha kukagesi kanye nezindawo zokusebenza.