+86 18068001229 Ama-Transformer Afakwe Iphedi Yesigaba Esisodwa e-JZP: Ubunjiniyela Obunembile Bokusabalalisa Amandla Okuthembekile
Ama-transformer e-JZP afakwe ku-pad esigaba esisodwa aklanyelwe ukudlula amazinga omhlaba wonke ngenkathi enikeza ukuguquguquka okungenakuqhathaniswa nokuqina kwezinhlobo ezahlukene Ukusatshalaliswa Kwamandla izidingo. Yakhelwe ukuhambisana nokudlulaIzindinganiso ze-ANSI, IEEE, DOE, CSA, kanye ne-NEMA, lawa ma-transformer afaka izici zokuphepha ezithuthukisiwe kanye nokwakhiwa okuqinile, okuqinisekisa ukusebenza kahle kwezicelo zezimboni, zezentengiselwano, kanye nezezindlu.
Izici Eziyinhloko Nezincazelo
Ukuthobela Nokuphepha
- Iqinisekiswe ngokugcwele ngeUhlu lwe-UL/cUL, CSA, futhi kwahlolwa ukuzeI-ANSI IEEE C57.12.00,I-CSA C22.2 Inombolo 66, kanyeIzilinganiso zokusebenza kahle ze-DOE 2016.
- Ihlonyiswe ngeUketshezi lwe-Envirotemp FR3™ukuze kuthuthukiswe ukumelana nomlilo kanye nokuphepha kwemvelo, kanye nezinketho zendabuko zamafutha okuvikela amaminerali.
Ukucushwa Okungenziwa Ngokwezifiso
- Ububanzi Bomthamo: 15–250 kVA, evumelana nezicelo ezivela ezinhlelweni zokuhlala ezincane kuya emithwalweni yezimboni esindayo.
- Ukuguquguquka kwe-Voltage:
- Ama-voltage ayinhloko: 34.5 kV–7.2 kV (amabanga angenziwa ngezifiso ayatholakala).
- Ama-voltage esibili: 120–600 V (120-240 V, 240-480 V, 347/600 V, noma izixazululo ezenzelwe wena).
- Izinketho Zokuphakelayo: Ukucushwa kwe-Loop noma i-radial ukuze kuhambisane nezidingo zegridi.
Ukwakhiwa Okuqinile
- Izinto Zokuhlala: Insimbi ethambile noma ongayikhethaAmathangi ensimbi engagqwali angu-304ukumelana nokugqwala ezindaweni ezinzima.
- Ukushisa Nokupholisa: Izinhlelo zokuvikela ezithuthukisiwe kanye nokupholisa kwe-convection yemvelo ukuze kuphathwe ukushisa okuthembekile.
- Izilinganiso ze-BIL: 30–150 kV, okuqinisekisa ukuqina kokumelana nokunyuka kwamandla kagesi.
Ukusebenza Kahle Nokusebenza Kahle
- Imiklamo esebenza kahle kakhulu ehambisana ne-Izindinganiso zamandla ze-DOE 2016, ukunciphisa izindleko zokusebenza.
- Ama-windings alahlekelwa kancane kanye nama-magnetic cores athuthukisiwe athuthukisa ukonga amandla.
Izesekeli Nokuhlanganiswa
- Iyahambisana nemikhiqizo ye-premium efanaI-ABB, i-Eaton, kanye ne-Qualitrolukuze kuthuthukiswe ukusebenza (isb., izinhlelo zokuqapha, ukuvikelwa kokukhuphuka kwejubane).
- Izishintshi zempompi ezingenziwa ngezifiso (ukulungiswa okungu-2×2.5%) ukuze kulawulwe i-voltage ngendlela enembile.
Ukukhiqizwa Nokulethwa
- Umthamo: PhezuAmayunithi angu-600 ngenyanga, ukuqinisekisa ukushintshwa okusheshayo ngaphandle kokubeka engcupheni ikhwalithi.
- Isikhathi esiholayo: Ukulethwa okusheshayo kuAmaviki angu-4–8, isekelwa inqubo yokukhiqiza elula.
Kungani Ukhetha i-JZP?
Ama-transformer e-JZP aklanyelwe ukuhlala isikhathi eside, ukusimama, kanye nokuzivumelanisa nezimo. Kungakhathaliseki ukuthi kuthuthukiswa izinhlelo ezindala noma kusetshenziswa ingqalasizinda entsha, izixazululo zethu zibeka phambili ukuphepha, ukusebenza kahle, kanye nokuthobela imithethoIzinketho ezingenziwa ngezifiso—kusukela ezilinganisweni zamandla kagesi kuya ezintweni zokwakha—ziqinisekisa ukuhlanganiswa okungenamthungo kunoma iyiphi igridi yamandla.
Ukuze uthole imibhalo yobuchwepheshe enemininingwane noma ukuxoxa ngezidingo zephrojekthi ethile, xhumana nethimba lobunjiniyela le-JZP namuhla.