Leave Your Message
Izigaba Zezindaba
Izindaba Ezivelele

Ngaphakathi kwe-JZP's Three-Phase Pad-Mounted Transformer: Ukucwila Ngokujulile Ekusunguleni Okuhlakaniphile Kwegridi

2025-07-10

I-Inside-JZP's-Three-Phase-Pad-Efakwe-I-Transformer--I-Deep-Dive-in-Smart-Grid-Innovation.jpg

Ezweni elishintshashintshayo lobuchwepheshe begridi ehlakaniphile, ama-transformer e-JZP anezigaba ezintathu (ama-PMT) avele njengesixazululo esishintsha umdlalo ukuze kube nokusebenza kahle. Ukusatshalaliswa Kwamandla. Ngokuhlanganisa umklamo omncane nobunjiniyela obusezingeni eliphezulu, lawa "ma-smart energy hubs" achaza kabusha ukuthembeka kanye nokusimama. Ake sihlole ukwakheka okuyinkimbinkimbi kwama-PMT e-JZP bese sithola izimangaliso zobuchwepheshe ezinika amandla ingqalasizinda yesimanje.

1. ​Ukwakhiwa Kwemodeli: Iseli Lamandla Elihlakaniphile​
Ama-PMT e-JZP asebenzisa umklamo "we-SmartCube" oguqukayo ohlanganisa izinhlelo ezintathu ezibalulekile endaweni eyodwa, engangenisi isimo sezulu:

Igumbi Elinamandla Aphezulu: Izinkinobho zokuvala umthwalo ezivalwe nge-vacuum ezine-SF6 gas insulation
I-Transformer Core: I-amorphous alloy core ethuthukisiwe enciphisa ukulahleka kwamandla
Ukusatshalaliswa Kwamandla Aphansi: Abalawuli be-logic abahlelekayo abanokuxhumeka kwe-IoT

Lo mklamo unciphisa isikhathi sokufakwa ngo-60% uma kuqhathaniswa neziteshi ezincane zendabuko futhi uthatha indawo engaphansi ngo-40%.

2. ​Isistimu Enamandla Kakhulu: Ubunjiniyela Bokuphepha Okokuqala​
2.1 Uhlelo Lokuvikela Oluhlanganisiwe
Isivimbeli Sokushaqeka: Kulinganiselwe ugesi we-short-circuit ongu-63kA onemisebenzi yomshini engu-10,000
AmaFusi Okuzwa Okubili: Ukuqapha izinga lokushisa + ukuqapha ugesi ukuze kuvikelwe kusengaphambili
Ukukhiya Kwemishini: Kuvimbela ukunikezwa kwamandla ngengozi ngesikhathi sokulungiswa
2.2 ​Ama-Smart Bushings​
Ama-Polymer Insulators: Amelana namandla ensimu angu-100kV/m
Ukumaka kwe-RFID: Kuvumela ukuqapha isimo okungahlaseli
Ukuzihlanza: Kunciphisa ukungasebenzi kahle okuhlobene nokungcola ngo-75%

3. ​I-Transformer Core: Ubuchwepheshe Bamagnetic​

3.1 Ubuchwepheshe be-Amorphous Alloy

Ipharamitha

Ukucaciswa kwe-JZP

Izinga Lemboni

Ukulahlekelwa Okuyinhloko (W/kg)

≤0.12 @50Hz

0.35

Ubuningi be-Magnetic Flux

1.45T

1.5T

Izinga Lomsindo

≤45dB(A)

≤55dB(A)

Umklamo we-​triple-leg stacked core​ wehlisa ukulahlekelwa kwamanje kwe-eddy ngo-40% ngezindlela ezilungiselelwe kahle ze-flux

3.2 ​I-Active Cooling Matrix​
Izendlalelo zezinto zokushintsha isigaba (PCM): Zimunca ukushisa okungu-300kJ/m³
Amafin Akhuthaza I-Vortex: Thuthukisa ukujikeleza kwemvelo ngo-250%
Izindlela Zokupholisa Ezihlanganisiwe: Shintsha ngokuzenzakalelayo phakathi kokushintshana komoya/imisebe ngokusekelwe kumthwalo


4. Uhlelo Lwe-Voltage Ephansi: Ubuhlakani Obusebenzisana Negridi

Ukulungiswa Kwamandla Ashukumisayo
Isinxephezelo se-VAR esiguquguqukayo: Sigcina i-PF >0.98 kuzo zonke izimo zomthwalo
Ukunciphisa i-Harmonic: Isihlungi esisebenzayo se-oda lesi-4 sikhansela ama-harmonics afinyelela ku-25
Ukuvimbela Ukuphela Kokukhanya: Ukudluliselwa okungenamthungo ku-UPS nge-

5. Iphakheji Yokumelana Nemvelo​
5.1 Ukuvikelwa Kwezinga Lezempi​
Isilinganiso se-IP68/IP69K: Sisinda ekucwilisweni emanzini angama-2m imizuzu engama-30
Ukumelana Nenkungu Kasawoti: Kudlula ukuhlolwa kwe-ASTM B117 kwamahora ayi-1000
Ukuvikela i-EMI: 5.2 Izinto Ezinobungani Nemvelo​
I-Dielectric Fluid Ebolayo: i-ester esekwe ezitshalweni engu-100%
I-Aluminium Engaphinde Isetshenziswe: Izinto ezingaphinde zibuyiselwe ezingama-98%
Umklamo Wokuvuza Okunga-Zero-Oil: Kusetshenziswa ukugcinwa kwe-nitrogen ecindezelwe

6. Izici Zokuhlanganisa Igridi Ehlakaniphile
Isixhumi Esisebenzisana Namandla Asakazwayo (i-DER): Sisekela ukuhlanganiswa kwe-solar PV/Storage
Ukubuyiselwa Kwe-Dynamic Voltage (DVR): Kugcina ukuqina kwe-voltage engu-±1%
Isango Lokuphendula Isidingo: Lihlanganyela ezimakethe zezinsizakalo ezihambisanayo

Izindaba Zempumelelo Yesicelo
Ama-Microgrid ase-Urban: Anika amandla izindlu ezingaphezu kuka-15,000 eDolobheni Elihlala Njalo lase-Dubai
Izixazululo Zesikhungo Sedatha: Isikhathi sokusebenza esingu-99.999% sezikhungo ze-AWS eSingapore
Ukufakwa kukagesi esitimela: Ukuguqulwa kwe-AC/DC okungu-25kV kwezitimela ezihamba ngesivinini esingu-300km/h

Xhumana ne-JZP Namuhla​
Unjiniyela Ikusasa Lakho Lamandla Ngezixazululo Zokuguqula Ezihlakaniphile
Usekelo Lobuchwepheshe: +86 16655239333

Zonke izincazelo zobuchwepheshe zihambisana nezindinganiso ze-IEC 60076-11 kanye ne-UL 1561.
Ukunika amandla igridi yakusasa namuhla – Izixazululo Zamandla ze-JZP