+86 18068001229 Ukwakheka kanye Nomklamo Wesakhiwo Sokuguqulwa Kwe-Amorphous Alloy (Umbono Wezobuchwepheshe we-JZP)
Isiguquli se-Amorphous Alloys, eqanjwe yizinkampani ezifanaI-ejensi Yezempilo Yomphakathi, imelela intuthuko yokuguqula izinto Ukusatshalaliswa Kwamandla ubuchwepheshe. Isakhiwo sabo esiyingqayizivele sisebenzisa izakhiwo zangaphakathi ze-alloys zensimbi ezingenasimo ukuze kufezwe ukusebenza kahle okungenakuqhathaniswa kanye nokusimama. Ngezansi kukhona ukuhlukaniswa okuningiliziwe kokwakheka kwabo kanye nokusungula izinto ezintsha, kugxilwe kakhulu ezixazululweni zobunjiniyela ze-JZP.
1. Isakhiwo Esiyinhloko: Inhliziyo Yokusebenza Kahle
I-amorphous alloy core iyisici esiyinhloko sama-transformer e-JZP. Ngokungafani nama-silicon steel cores endabuko, i-JZP isebenzisa amaribhoni angenasimo acwebezelayo kakhulu(ukujiya isakhiwo se-athomu esingeyona ikristalu
Lawa ma-ribbon yilawa:
Kwenziwe ngokuncibilikisa: I-JZP isebenzisa amasu okucima ngokushesha ukukhiqiza amaribhoni anekristali encane, iqinisekisa i-hysteresis ephansi kanye nokulahleka kwamanje kwe-eddy
Inxeba libe yisimo se-toroidal: Ingqikithi ihlanganiswa ngokugoqa amaribhoni njalo ibe yisakhiwo esiqinile nesivalekile. Lokhu kunciphisa ukuvuza kwe-magnetic flux futhi kuthuthukisa ukusebenza kahle kwamandla ngamaphesenti afinyelela ku-80 uma kuqhathaniswa nama-transformer avamile.
Kufakwe ama-alloy e-boron-silicon: I-JZP ithuthukisa ukwakheka kwe-alloy (isb., i-Fe₇₈B₁₃Si₉) ukuze kufezwe ubuningi bokugcwala kokugcwala okungu-1.5–1.8 T, okuvumela amavolumu amancane ayisisekelo ngaphandle kokuphazamisa ukusebenza
Ukuqamba kabusha kwe-JZP:
"Ukuhlanganiswa Kwezingqimba Eziningi" Okunelungelo Lobunikazi: Kunciphisa ukucindezeleka kwangaphakathi kumaribhoni, kuthuthukisa ukuzinza komshini ngesikhathi sokugoqa.
Ukuthuthukiswa kwe-Dynamic Flux: Ilungisa i-geometry eyinhloko ukuze ivumelane nokushintshashintsha komthwalo, inciphisa ukulahlekelwa kokusebenza ngo-15%
2. Ama-Windings: Ukunemba Nokuqina
Ama-winding e-JZP aklanyelwe ukuqhuba kahle kakhulu kanye nokuqina kokushisa:
Umqhubi Wethusi/we-Aluminium: Ama-windings ethusi ahlanzekile kakhulu (99.99%) anciphisa ukulahlekelwa okunamandla. Ngezinhlelo zokusebenza ezibiza kakhulu, i-JZP inikeza ama-windings e-aluminium anokusebenza okulinganayo.
Ukufakwa kwe-VacuumAma-winding afakwe ku-epoxy resin ngaphansi kwe-vacuum ukuze kususwe amaphakethe omoya, okuqinisekisa ubuqotho bokufudumeza ngaphansi kwamazinga okushisa aphezulu.
Ukucushwa Kokuxhumeka kwe-Dyn11: Lokhu kuhlelwa kokugoqa kuvimbela ukuhlanekezela kwe-harmonic (isb., i-harmonic yesithathu) ngokulinganisa ukugeleza kwesigaba, okubalulekile kumagridi ezimboni anemithwalo engeyona eye-linear.
Ukuthuthukiswa kwe-JZP:
Ubuchwepheshe Bokugoba Obuguquguqukayo: Isebenzisa izingalo zerobhothi ezinokulawula ukucindezeleka okuqhutshwa yi-AI kumaribhoni omoya ngaphandle kwemifantu emincane, okwandisa impilo yesevisi ngo-30%
3. Ukuphathwa Kokushisa Nokushisa
Izendlalelo Zokuvimbela EziqinileI-JZP iqasha iphepha le-nomexfuthi amafilimu e-polyesterukuhlukanisa ama-windings kusuka enkabeni, alinganiswe amandla e-dielectric angu-35 kV/mm.
Umklamo Wethangi Eligcwele Uwoyela:
Ibhokisi Elivaliwe: Kuvimbela ukungena komswakama kanye nokubola, kuhambisana nezindinganiso ze-IEC 60599
Amafin Okupholisa: Amaphiko e-aluminium ahlanganiswe ethangini athuthukisa ukushabalaliswa kokushisa, anciphisa amazinga okushisa okusebenza ngo-10–15°C
Intuthuko ye-JZP:
Ukuzivikela OkuziphilisayoAma-resin epoxy athuthukiswe yi-nanoparticle alungisa ngokwawo amaphutha amancane okushisa, okunciphisa izidingo zokulungisa
4. Ukuhlanganiswa Kwesakhiwo Nezinselele
Umhlangano Wokujika OkuyinhlokoUkusetshenziswa kwe-JZP amalunga afakwe nge-laserukuxhuma amaribhoni, ukunciphisa izikhala zomoya kanye nokumelana nomagnetic.
Ukuqinisa Okwenziwa Ngemishini: Ozimele be-polymer abaqiniswe nge-fiberglass basekela umongo, banciphise ukukhathala okubangelwa ukudlidliza.
Izinselele Eziyinhloko Ezixazululwe Yi-JZP:
Ubulukhuni beRibhoni: Yakha inqubo "yokucindezela ngaphambi kokusebenzisa" ukwandisa ukuguquguquka kweribhoni ngesikhathi sokuphatha.
Ukusebenza Kahle Kwezindleko: Ama-algorithms okusika iribhoni alungiselelwe ukunciphisa imfucuza yezinto ezibonakalayo ngo-25%
5. Amamethrikhi Okusebenza kanye Nezicelo
| Ipharamitha | I-JZP Amorphous Transformer | Isiguquli Sensimbi Yesi-Silicon Sendabuko |
| Ukulahlekelwa Okungenamthwalo | 0.15–0.3 W/kVA | 0.8–1.2 W/kVA |
| Ukulahlekelwa Umthwalo | 1.2–1.8 W/kVA | 2.5–3.5 W/kVA |
| Ukusebenza kahle | >98% | 92–95% |
| Izinga Lomsindo | ≤45 dB | 55–65 dB |
Izicelo:
Amagridi Ahlakaniphile: Kuhle kakhulu ukusatshalaliswa emadolobheni ngenxa yomsindo ophansi kanye nosayizi omncane.
Amandla Avuselelekayo: Ihlangana kahle nezinhlelo zelanga/zomoya ukuze kuguqulwe i-DC-AC ngendlela ephumelelayo
Isiphetho
Ama-transformer e-alloy angenasimo se-JZP abonisa ukuhlanganiswa kwesayensi yezinto ezibonakalayo kanye nokukhiqizwa okuthuthukile. Ngokucabanga kabusha ukwakheka okuyinhloko, ukunemba kokugoqa, kanye nokuphathwa kokushisa, i-JZP ibeke amazinga amasha okusebenza kahle kwamandla, okwenza la ma-transformer abe yinto ebalulekile engqalasizinda yamandla esimeme. Ukuze uthole imininingwane eyengeziwe yobuchwepheshe, bheka imibhalo yomkhiqizo ye-JZP noma uthintane nethimba labo lobunjiniyela.