Izinzuzo

 

1.​Ukupholisa Okuphezulu Nokushabalalisa Ukushisa
I-Transformer Ecwiliswe Kuwoyelas zisebenzisa uwoyela wokuvikela ukuze zimunce futhi zidlulise ukushisa kahle. Umthamo wokushisa ophezulu kanye nokushisa okuphezulu kwamafutha kwenza kube lula ukusebenza ngaphansi kwemithwalo esindayo, okwenza kube kuhle kakhulu ekusetshenzisweni kwamandla kagesi aphezulu.

 

2.Izakhiwo Ezinhle Zokuvimbela Ukushisa
Uwoyela we-transformer usebenza njengendlela enamandla yokudlulisa ugesi, uvimbela ukuphuka kukagesi kanye nama-short circuits. Ungena ezintweni zokuvikela njengephepha, uthuthukise ukuqina kwawo futhi wandise isikhathi sokuphila kwe-transformer.

 

3.Ukusebenza Kahle Kwezindleko
Izindleko zokukhiqiza zokuqala ziphansi uma kuqhathaniswa ne I-Transformer Yohlobo Olomiles, kanye nokonga kokusebenza kuvela ekusebenzeni kahle kakhulu (98–99%) kanye nokulahlekelwa amandla okuncishisiwe. Izindleko zokulungisa ziyalawuleka ngezinqubo ezijwayelekile njengokuhlolwa kwamafutha kanye nokuhlunga

 

4.Umthamo Ophakeme Wokulayisha
Ukungabi namandla okushisa kwamafutha kuvumela ukugcwala ngokweqile kwesikhashana ngaphandle kokwenyuka okukhulu kwezinga lokushisa, okwenza lawa ma-transformer afanelekele imithwalo yezimboni eguquguqukayo

 

5.Impilo Ende Yenkonzo
Uma kunakekelwa kahle, ama-transformer acwiliswe ku-oyela angasebenza ngokuthembekile iminyaka engama-20-40. Izakhiwo zokuziphilisa zamafutha (isb., ukukhiqizwa kwegesi ngesikhathi sokutholwa kwamaphutha) zithuthukisa ukuqina kwawo.

 

 

Ukungalungi

 

1.Izingozi Zomlilo Nokuqhuma
Uwoyela wamaminerali unephuzu lokukhanya elingu-~140°C, okubeka izingozi zomlilo ngesikhathi sezimo zokungasebenzi kahle. Ama-firewall kanye nezinhlelo zokulawula uwoyela kuyimpoqo, okwandisa ubunzima bokufakwa kwawo.

 

2.Ukukhathazeka Ngezemvelo
Ukuvuza kwamafutha kungangcolisa inhlabathi namanzi, kudinga ukuvalwa okuqinile kanye nezindlela ezikhethekile zokulahla. Amafutha e-ester okwenziwa aphephile kodwa abiza kakhulu

 

3.Izidingo Zokulungisa
Ukuhlolwa kwezinga likawoyela njalo, ukuhlolwa komswakama, kanye nokuhlaziywa kwegesi (isb., ukuhlaziywa kwegesi encibilikisiwe) kuyadingeka. Uwoyela ogugile udinga ukushintshwa noma ukuhluzwa.

 

4.Ubukhulu kanye nesisindo
Amathangi kawoyela nezinhlelo zokupholisa zenza lawa ma-transformer abe makhulu futhi abe nzima, okunciphisa ukusetshenziswa kwawo ezindaweni ezincishisiwe njengezakhiwo zasemadolobheni.

 

5.Izinselele Zesimo Sezulu Esibandayo
Emazingeni okushisa aphansi, ukujiya kwamafutha kuyanda, okuphazamisa ukushabalaliswa kokushisa. Amafutha asekelwe ku-silicone angadingeka, okwandisa izindleko zokusebenza

 

 

Ukuqhathaniswa nama-Transformers Ohlobo Olomile

  • Ukusebenza kahle: Ama-transformer acwiliswe uwoyela asebenza kahle kakhulu kunezinhlobo ezomile ngenxa yokupholisa okuphezulu kanye nokulahlekelwa amandla okuphansi.
  • UkuphephaIzinhlobo ezomile azishisi futhi zifaneleka ezindaweni zangaphakathi/zasemadolobheni kodwa azisebenzi kahle futhi zibiza kakhulu isikhathi eside.
  • Izicelo: Ama-transformer acwiliswe uwoyela alawula amagridi kagesi kanye nezitshalo zezimboni, kuyilapho izinhlobo ezomile zithandwa ezindaweni ezibucayi

 

Isiphetho

Ama-transformer acwiliswe ku-oyili avelele kakhuluizinhlelo zokusebenza zamandla aphezulu, ezinamandla aphezulungenxa yokusebenza kahle kwazo, ukuqina kwazo, kanye nokusebenza kahle kwezindleko. Kodwa-ke, izinselele ezifana nezingozi zomlilo kanye nomthelela wezemvelo zidinga ukunciphisa ngezinyathelo zokuphepha ezithuthukisiwe kanye nokusetshenziswa kwamafutha okwenziwa. Ezindaweni ezilinganiselwe noma ezizwela imvelo, ama-transformer ohlobo olomile anikeza enye indlela esebenzayo naphezu kwezindleko eziphezulu kusengaphambili.